Low outlet pressure is one of the common failures of piston type liquid oxygen pumps. The causes of low outlet pressure are usually wrong pump steering, insufficient speed, steam in the pump or a blocked inlet filter. If a piston liquid oxygen pump has a low outlet pressure fault, stop the pump to check the cause. If the steering is wrong, change the motor wiring. If there is steam in the pump, the exhaust line needs to be opened and re-cooled. If the filter is clogged, it needs to be disassembl...
May 11, 2022
Convective heat transfer is one of the ways in which heat is transferred from a high temperature object to a low temperature object, using the flow of a fluid to transfer heat from one part of the fluid to another. The strength of convective heat transfer is expressed in terms of the heat transfer coefficient, which is influenced by the type of fluid. In addition to this, the state of flow of the fluid, the dynamics of the fluid that produce the flow and the shape of the radiating surface all af...
May 10, 2022
ypes of weld defects in air separation equipment cast steel parts The morphology of cast steel defects on radiographs differs from that of welding defects, and the correct identification distinguishes the types of defects  Inclusions 1 Metal inclusions Metal inclusions are mainly mixed in the casting metal melt in other kinds of metal pieces. It has a certain geometry, size of density and atomic number compared to the casting metal. Its image may appear as a lower or higher blackness th...
May 07, 2022
The raw air is compressed to 0.50 MPa in an air compressor after passing through an air filter, cooled by a pre-cooling system, and then enters the molecular sieve adsorber for switching. After being pre-cooled and purified, the majority of the air eventually enters the fractionation column. The purification system has two molecular sieve adsorbers, one working while the other is regenerated (the large air separation unit uses the heating regeneration method) and the two adsorption drums work al...
May 05, 2022
The small air separation units, large air separation units and liquid air separation plants use ambient temperature molecular sieve adsorption purification, pressurized turbine expander cooling, liquid oxygen evaporator pressurization, gauge packing distillation, and DCS system control of the self-pressurization process. All systems are operating normally. The regenerated molecular sieves were not thoroughly regenerated and a vicious cycle occurred, increasing operating costs and risks. Operati...
Apr 29, 2022
Many factors affect the centrifugal compressor exhaust volume, in addition to design, manufacturing, installation, in addition to the operation of large air separation units compressor can affect the exhaust volume of the main factors are. 1) Air filter blockage or increased resistance, resulting in lower compressor inlet pressure. 2) air separation equipment pipeline blockage, increased resistance or valve failure, triggering the air compressor exhaust pressure rise. 3) compressor intercoole...
Apr 26, 2022
According to the shape, size, location and protection conditions of the cast steel parts, choose the appropriate transmission method. In the case of implementation should be given priority to single-wall transillumination, in the single-wall transillumination can not be implemented before allowing the use of double-wall transillumination method. In practice, single-wall external transmission method, internal transmission eccentric method, internal transmission centre method, double-wall transmis...
Apr 25, 2022
Steel plate coil pipe, which is rolled and welded from steel plates, is divided into two types of straight seam coil welded steel pipe and spiral seam coil welded steel pipe. LSAW steel pipe: most of the construction site manufacturing or commissioned processing plant manufacturing, professional steel pipe factory does not produce. Steel plate material Q235A, No. 10, No. 20, 16Mn, 20g, etc., its specifications range from 200 to 3000mm nominal diameter, the largest with 4000mm, wall thickness ge...
Apr 21, 2022
Oxygen is a strong oxidising gas, flammable and explosive, so safety measures should be taken in its design and manufacture. When choosing materials, all metals in contact with oxygen must be chemically stable and not easily oxidised. Each component should be degreased. The shaft seal should be sealed with nitrogen pressure difference and also ensure the vacuum of the oil system. All large air separation unit parts and pipings in contact with oxygen should be earthed to prevent static electricit...
Apr 19, 2022
The acetylene content in liquid air and liquid oxygen needs to be analysed every day, so the liquid air and liquid oxygen discharge valves have to be operated every day. The problem arises when it is easy to open the valve, but difficult to close it, sometimes even a little can not be closed. This is mainly due to the presence of moisture at the valve stuffing box. When the liquid is discharged, the temperature drops and freezing occurs. In order to prevent this, the valve should be turned cont...
Apr 15, 2022
The clean air chamber outlet of the self-cleaning air filter is connected to the air compressor inlet, where process air is drawn in from the atmosphere under negative pressure. The air passes through the filter cartridge and the dust is blocked by the filter media. Numerous small particles of dust form a dust film on the windward surface of the filter media. The dust film improves the filtration effect, but also increases the resistance to airflow. When the resistance increases to a high limit...
Apr 13, 2022
1.Operators should adjust the discharge volume in time so that the concentration times are within the index. 2.Every week, a large amount of sewage should be discharged once. Discharge the sewage from the drainage pipe at the bottom of the tower. 3.Regularly analyse the calcium loss rate. Calcium loss rate is used to assess the system scaling situation, in general, calcium loss rate ≤ 20%. 4.Monitor the cooling water analysis once a week. Main analysis items: pH, conductivity, total phosph...
Apr 11, 2022
1...8 9 10 11 12 13 14 15...24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top