Large air separation unit argon purification stage

Large air separation unit argon purification stage
May 13, 2022
Author: DEAR AST

The cooling of the argon system of the large air separation unit should be carried out simultaneously with the cooling of the main tower system. After the cooling of the argon system, even if the argon system is not put into operation, a certain amount of cold should be introduced to the argon system to keep the argon system always in a cold state. Argon system can choose to adjust the pure and the main tower at the same time, more appropriate to wait for the main tower system adjustment is normal and then adjust:

1, the process liquid argon pump must wait for the main tower system to be adjusted.

2, the process liquid argon pump must be to the bottom of the crude argon tower liquid level to reach the design of the liquid level before starting.

3, start the process liquid argon pump before the Ar condenser should retain a certain liquid level.

4, adjust the pure stage should first adjust the Ar purity and then adjust the Ar output.

5, crude argon tower I, II should be depending on the respective resistance value and argon fraction containing Ar gradually increase the load, at the same time must pay attention to the O2, N2 content of the gas pumped from the top of the crude argon tower II.

6, the valve should be depending on the crude argon gas containing O2, N2 amount gradually and slowly open large. Adjust the valve opening to control the resistance of the pure argon tower, at the same time to control the amount is not too large.

7, adjust the pure stage should first ensure that the main tower system purity is not damaged. The pure stage must pay close attention to the analysis value of each analysis point, depending on the specific situation to adjust.

8、The output of the Ar system must be changed with the change of the processing gas volume.

DEAR air separation small air separation units, large air separation units and liquid air separation plants manufacturing technology is mature and standardised to ensure safe operation and maintenance, stable and efficient production.

上海宝冶集团有限公司-7500(2)

DEAR Air Separation Solve YourLarge air separation unit argon purification stageYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The air cooling tower is the core equipment of the air separation precooling system, which is mainly used to cool and wash the high-temperature compressed air discharged from the air compressor, provide qualified low-temperature gas source for subsequent molecular sieve purification and cold box rectification, and ensure the stable operation of the whole unit. The air cooling tower adopts the countercurrent packing heat exchange structure, the tower is filled with high-efficiency packing, and the top is equipped with a spray device and a wire mesh demister. During operation, the high-temperature compressed air at 80 to 100 ℃ discharged by the air compressor enters from the bottom of the tower and flows from bottom to top; The cooling water is the normal temperature make-up water and the low-temperature chilled water prepared by the water-cooling tower, which is sprayed from top to bottom from the tower top, and the air and water are fully contacted in reverse for heat exchange. Under t
2026.11.12
Regulation of liquid nitrogen throttle valveThe opening of the liquid nitrogen throttle valve not only affects the reflux ratio of the upper tower, but also affects the reflux ratio of the lower tower. When the opening is increased, the reflux ratio of the upper tower increases, while the reflux ratio of the lower tower decreases, the purity of the nitrogen in the upper tower increases, and the purity of the oxygen enriched night sky in the lower tower increases. However, after the opening is over, the purity of the liquid nitrogen decreases, and the reduction of the reflux ratio of the upper tower is also detrimental to the improvement of the purity of the liquid oxygen. Therefore, an equilibrium point should be found for the opening of the liquid nitrogen throttle valve. We can generally use the purity difference between liquid nitrogen and gas nitrogen to judge whether the opening is appropriate. Generally, the purity of the sprayed liquid nitrogen is equal to that of the upper towe
2026.11.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top