The joint working point of compressors and pipe networks in small air separation units

The joint working point of compressors and pipe networks in small air separation units
May 13, 2022
Author: DEAR AST

The centrifugal compressor and the pipe network form a system of energy supply and use in which the compressor is the energy supplier and the pipe network is the energy user, each of which has its own characteristic curve. When they work together, the energy system can only be balanced when the flow rate through the compressor and the energy head generated by the compressor are equal to the energy of the pipe network and the resistance of the pipe network respectively. This is the intersection of the compressor and pipe network characteristic curve, that is, the joint working point.

DEAR air separation independently developed and manufactured and installed high-purity nitrogen small air separation units KDN-2200, after installation, linkage test, a successful commissioning, the official output of nitrogen products, stable operation after 72 hours, nitrogen output ≥ 2200m³ / h, purity ≤ 100PPm. equipment unit operation of the technical indicators and energy consumption indicators have reached and exceeded the design requirements. The large air separation unit has met and exceeded the design requirements in all technical indicators and energy consumption, and passed the assessment. Both sides signed the acceptance report happily, and the small air separation units, large air separation units and liquid air separation plants of Kaifeng Deere Air Separation were highly evaluated by the customers.上海宝冶集团有限公司-7500

DEAR Air Separation Solve YourThe joint working point of compressors and pipe networks in small air separation unitsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Generally, the actual cooling capacity of expander is always less than the theoretical cooling capacity. Under the same inlet and outlet pressure and inlet gas temperature, the lower the efficiency of expander, the smaller the unit refrigerant cooling capacity and the smaller the temperature drop efficiency of expander. The efficiency of expander depends on the size of various losses inside the expander. Due to the existence of various losses, the ability of gas to do external work is reduced in varying degrees. To sum up, the losses mainly include the following aspects: 1. When the air flow passes through the work wheel and the deflector, the loss caused by friction and air flow impact on the runner surface is called flow loss. 2. When the impeller is rotating, the friction heat generated by the gas around the wheel disc will increase the temperature of the gas, which is called friction blast loss. 3. When the gas passes through the deflector, the leakage from the gap bet
2025.11.07
The principle and function of molecular sieve purification system in air separation equipment?
2025.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top