当前位置: Home / FAQ /

Liquefied air separation FAQ

Liquid air separation plant solutions Most liquid air separation plant cold energy receiving stations have a peaking role, their use is generally for domestic gas or car refuelling, with high and intermittent periods of gas consumption, for example 1-2 hour peaks in the morning and midnight. If the liquid air separation plant vapourisation plant is intermittent, the plant will not operate continuously. The solution is based on the intermittent use of liquid air separation plant and is character...
Jul 08, 2026
The energy saving in liquid air separation plants improves the efficiency of the air compressor and consumes energy mainly in the air compressor and the circulating nitrogen press. In liquid air separation plants, the cold volume of liquid air separation plant is utilised in sections. The cold volume in the high temperature zone is pre-cooled by a glycol solution, and the compressed air of the air compressor allows the inlet temperature of each stage of the air compressor to be reduced from the ...
Jun 29, 2026
Liquid air separation plant cold energy utilises air separation equipment, generally large air separation equipment with 2 combined expanders. The price is around 4 million RMB. The expansion air in the air separation plant is no longer required, so for the internal compression process air separation, the inlet air volume of the circulating booster is reduced by about 40% (from 5.A-2A). The energy consumption of the booster is reduced and the investment is reduced. Liquid air separation equipmen...
Jun 18, 2026
Effective energy analysis is an important analytical method for energy systems. liquid air separation plant is a low-temperature liquid mixture with methane as the main component, including nitrogen, ethane, propane and other components, which has a large temperature difference and pressure with the outside world. liquid air separation plant is a low temperature liquid and its temperature rise is accompanied by phase change heat, so its cold energy is divided into sensible heat and lat...
Jun 10, 2026
Water evaporation, wind-blown losses and other situations occurring in industrial circulating cooling water system operation, resulting in the continuous concentration of circulating water, then the salts contained therein exceed the standard, anions and cations increase, PH value changes significantly, resulting in the deterioration of water quality. The temperature of the circulating water rises and the PH value and nutrients increase, which is conducive to the reproduction of microorganisms. ...
Jun 03, 2026
How to prevent water inflow accident of molecular sieve purification system of air separation equipment?
May 21, 2026
With the rapid growth of liquid air separation plant production and sales, and the global energy crunch, the prospects for the use of liquid air separation plant cold energy are very broad. The use of liquid air separation plant cold energy should be developed in the direction of integration, fully integrated and effective use of liquid air separation plant cold energy liquid air separation units, using circulating nitrogen through the heat exchanger to recycle liquid air separation plant cold, ...
May 13, 2026
The relative values of low temperature effective energy and pressure effective energy are variable and the application of liquid air separation plant cold energy is based on the specific use of liquid air separation plant, combined with specific processes to effectively recover liquid air separation plant. In fact the essence of liquid air separation plant cold energy utilisation is the transfer of liquid air separation plant cold to the mass to be cooled to achieve the ...
May 06, 2026
What is the working principle of air cooling tower and water cooling tower of air separation equipment?
Apr 27, 2026
Another part of the nitrogen vaporized in the liquefier is heated up to a certain temperature in the high pressure heat exchanger and pumped out to the low pressure nitrogen press, the nitrogen separated by the gas-liquid separator is also heated up by the high pressure heat exchanger and then goes to the low pressure nitrogen press, compressed to a certain pressure by the low pressure nitrogen press and then back to the high pressure heat exchanger for heat exchange with liquid air separat...
Apr 17, 2026
The liqued air separation plant cooling capacity is cooled between the air compressor and the nitrogen compressor, resulting in a significant reduction in energy consumption and a 50% saving in energy consumption. At the same time the introduction of liqued air separation plant cold capacity eliminates the chiller, expander, but increases the cold balance of the liquefier, in the heat transfer calculation is more difficult in low temperature conditions, the performance of the fluid changes more ...
Apr 09, 2026
In the liquid air separation plant, the cooled refrigerant goes to the air machine through the refrigerant delivery pipeline, and the intercooler cools the compressed air to around 10°C, improving the efficiency of the air compressor and reducing the energy consumption of the air compressor. The air separation unit uses circulating nitrogen to recycle and utilise the CNG cold through a heat exchanger, which in turn liquefies the air to transfer the cold to the liquid air separation plant, an...
Mar 31, 2026
1 2 3 4 5 6 7 8...15
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top