当前位置: Home / Faq / Liquefied air separation FAQ /

Types of problems with purifiers for liquid air separation plants

Types of problems with purifiers for liquid air separation plants
Apr 28, 2022
Author: DEAR AST

Brief description of the molecular sieve problem

The purifier CO₂ suddenly started to run abnormally and suddenly went out of range in liquid air separation plants, the dew point never changed significantly.

The dew point did not change significantly. In order to ensure that the other molecular sieve had enough time to regenerate, the time could not be shortened any further. At this point there was a relatively stable situation with no further deterioration. Check the trend graph for a cold blow peak of 135 degrees. Same as before. There was no reduction in the regenerated gas volume either. After the problem appeared, the process staff discussed and analysed together the possible causes.

1 The analysis table had drift and there was a leak in the analysis tube. There was nothing unusual about the analysis table with the standard gas calibration team. Using foam water to check for leaks, no leaks were found either. And the purifier was running CO₂ normally. This also means that there is no problem with the analysis table.

The purifier was analysed for water in the molecular sieve and the inlet temperature trend was carefully checked. There was no sign of water in the curves such as cold blow peak.

The steam heater was analysed for leaks and the trace water analyser was connected to the steam heater outlet and no significant change was found. And the other purifier could be operated normally.

The purifier was analysed for unevenness, uneven bed convexity and unevenness, caused by bias flow of gas volume. On closer analysis, this is not very likely, but if it is a bias flow, the phenomenon should be CO₂, which is getting worse and worse, which means that the switching time is getting shorter and shorter. Therefore, this is not very likely either.

The analysis shows that there is a leak in the alumina or molecular sieve of the purifier and that the screen is broken. At first the leakage is small, but later it increases, because the space under the molecular sieve adsorber is limited. The leakage reaches a certain level and a self-sealing phenomenon is formed. This is more in line with the exceedance of the standard at the site.

DEAR air separation installation and overhaul team of small air separation units, large air separation units and liquid air separation plants provides a 24-hour butler service.

沼气提纯设备-15000m³D-GZ

DEAR Air Separation Solve YourTypes of problems with purifiers for liquid air separation plantsYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why do the design, installation, and production of complete sets of air separation equipment require various parameters from the demand side?
2024.11.14
The classical single column process is the first one to be used in industrial application. However, there are many disadvantages in the classical single column process. One is that oxygen and nitrogen cannot be produced simultaneously, and the other is that the oxygen extraction rate can only reach about 70%. There are two improvement schemes to solve the defects of classical single column process. One is the curren...
2024.11.13
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top