What factors affects large air separation unit centrifugal compressor exhaust volumes?

What factors affects large air separation unit centrifugal compressor exhaust volumes?
Apr 26, 2022
Author: DEAR AST

Many factors affect the centrifugal compressor exhaust volume, in addition to design, manufacturing, installation, in addition to the operation of large air separation units compressor can affect the exhaust volume of the main factors are.

1) Air filter blockage or increased resistance, resulting in lower compressor inlet pressure.

2) air separation equipment pipeline blockage, increased resistance or valve failure, triggering the air compressor exhaust pressure rise.

3) compressor intercooler blockage or increased resistance, triggering a reduction in exhaust volume.

4) poor sealing of the compressor of large air separation units, resulting in gas leakage. Including:

① internal leakage, i.e., inter-stage gas fugitive. Make the compressed gas backward, and then a second compression.

② external leakage, i.e. gas leakage from the shaft end seal to the outside of the casing.

5) Large air separation unit cooler leakage. A leak refers to the water side pressure is higher than the gas side pressure, cooling water will enter the gas side channel, and further entrained by the airflow into the impeller and diffuser. After a certain period of time caused by scaling, blockage, so that the air flow is reduced. Second and third level cooler leakage is the pressure on the gas side is higher than the water side, the compressed air will leak into the cooling water to run off, so that the exhaust volume is reduced.

6) The frequency or voltage of the power grid drops, leading to a decrease in the speed of the generator and compressor, reducing the exhaust volume.

7) any level of suction temperature increases, the gas density decreases, also will cause the suction volume to decrease.

Dear air separation has many years of small air separation units, large air separation units and liquid air separation plants manufacturing performance, technical principles and process systems have research theory and practical experience.

沼气提纯设备-40000m³D-SM-(2)

 

DEAR Air Separation Solve YourWhat factors affects large air separation unit centrifugal compressor exhaust volumes?You can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What factors are related to the cooling capacity of the expander
2025.12.05
The raw air is compressed to about 0.52Mpa by the air compressor after filtering out dust and impurities, and then cooled to about 10℃ by the refrigerant glycol aqueous solution or Freon, and then enters the purification system to purify and remove water, carbon dioxide and other impurities in the air. Part of the raw material air enters the lower tower via the second raw material air pipeline, another part is liquefied into liquid air via the liquefier and enters the lower tower via the liquid ...
2025.12.04
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top