当前位置: Home / Faq / Liquefied air separation FAQ /

Liquid air separation plant circulating cooling water operation and control

Liquid air separation plant circulating cooling water operation and control
Apr 18, 2022
Author: DEAR AST
  1. According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index.
  2. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water.
  3. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is greater than 4, open up the drainage water and supplement clean water to make the concentration multiplier less than 4.

4、Control of total phosphorus in circulating cooling water. According to the performance characteristics of scale and corrosion inhibitors, the total phosphorus value in circulating cooling water in the range of 6~10mg is appropriate.

(1) If the discharge water is large, the total phosphorus is low, it is appropriate to add scale and corrosion inhibitor, so that the total phosphorus up to the required indicators, and adjust the discharge water.

(2) If the normal discharge of circulating water system, but the total phosphorus is low, it is necessary to analyze and check whether the drug is invalid or deviation is too large. After eliminating the above reasons, increase the amount of dosing, so that the total phosphorus up to the index requirements.

(3) If the total phosphorus in circulating water is greater than 10mg, no scale and corrosion inhibitor will be added.

Dear air separation cloud pattern team found circulating cooling water system operation and water treatment work in abnormal phenomena and problems, timely reporting and processing, to ensure that to meet the customer's product needs and small air separation units, large air separation units and liquid air separation plants quality standards.

山东钢铁集团(壶井)16000

DEAR Air Separation Solve YourLiquid air separation plant circulating cooling water operation and controlYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
More than half of all air separation equipment accidents were the explosion caused by the main cooling system. When processing air, all the impurities which have not been completely removed will finally gather in the main cooling liquid oxygen.
2024.05.17
1. Workers must wear safety helmets properly when entering the construction site, because the construction site is often chaotic. Some equipment installation sites, several construction teams are working at the same time, it is impossible to completely guarantee that there are no falling objects.2. Proper use of personal protective equipment, and carefully implement safety protection measures. When working on high places, cliffs and steep slopes without protective facilities, safety belts must b...
2024.05.16
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top