How to quickly determine and handle the failure of Molecular Sieve Purifier?

How to quickly determine and handle the failure of Molecular Sieve Purifier?
Oct 14, 2026
Author: DEAR AST

When the output of the air separation unit drops suddenly, the failure of the molecular sieve purifier is the core inducement of high frequency. It needs to be determined quickly and accurately and dealt with decisively to avoid more serious accidents caused by the freezing and blocking of the cold box.
First look at the core online indicators for judging the molecular sieve failure: the carbon dioxide content at the outlet of the purifier continues to be higher than 1ppm and does not fall back after switching, and the moisture dew point rises to above -65 ℃, basically confirming the adsorption penetration. Secondly, the regeneration curve was observed. The cold blowing peak value fell from above 120 ℃ to below 80 ℃ and the platform period was shortened, indicating that the adsorption capacity of molecular sieve decreased sharply and the analysis was not complete. Looking at the chain reaction at the back end, the temperature difference at the hot end of the main heat exchanger is increased, the resistance between the upper and lower towers is gradually increased, the liquid level of the main cooling is difficult to maintain, and the oxygen production and purity are simultaneously decreased, which are the secondary characteristics of molecular sieve failure.
It is necessary to strictly distinguish between true and false failures: the internal leakage of the program control valve, the failure of the regeneration heater, the excessive water in the air cooling tower, and the distortion of the instrument probe are all false failures. The molecular sieve itself is intact, and the valve and heating system can be recovered by troubleshooting; However, oil poisoning caused by air compressor oil leakage, long-term water hardening and pulverization, and expiration of service life are permanent failures, and the molecular sieve must be stopped and replaced.
Once the penetration failure is confirmed, the load shall be immediately reduced for operation, and the shutdown heating scheme shall be formulated simultaneously to thoroughly blow out the frozen water and carbon dioxide in the cold box, so as to prevent the sand removal maintenance caused by the complete blockage of the flow channel. It is necessary to strictly control the outlet water temperature and oil content of the air cooling tower, regularly detect the adsorption capacity of molecular sieve, and ensure the stable operation of the purification system from the source.

DEAR Air Separation Solve YourHow to quickly determine and handle the failure of Molecular Sieve Purifier?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
In the air separation refrigeration system, isentropic expansion and throttling expansion are two core cooling methods. The essential difference between the two determines the significant difference in refrigeration efficiency and application scenarios. Isentropic expansion is a process in which high-pressure gas drives the impeller to rotate through the expander and outputs shaft work to the outside. Under the ideal reversible condition, the entropy remains unchanged, that is, Δ s=0, and the internal energy is directly converted into mechanical work and removed from the system, so the cooling range is large and the cooling capacity is strong. There is a slight entropy increase in actual operation, which is close to the ideal degree measured by isentropic efficiency in engineering. Modern large and medium-sized air separation units use the isentropic expansion of the turbine expander as the main refrigeration source, and the expansion power can also be recovered for pressurization to f
2026.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top