What are the requirements for the main column of the argon column of the air separation column?

What are the requirements for the main column of the argon column of the air separation column?
Nov 25, 2026
Author: DEAR AST

An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower.
The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered.
The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen content of the extraction port should be controlled at 8% 12%. The design of the extraction channel of the main tower shall be reasonable, and the extraction volume shall not be too large, so as to prevent damage to the gas-liquid load and reflux ratio of the upper tower and to avoid deterioration of the purity of oxygen and nitrogen products.
The reflux ratio of the main tower must be stable. Focus on the control of the liquid oxygen surface of the main cooling system, the liquid level of the lower tower and the return flow of liquid nitrogen. Once the working condition of the main tower fluctuates, the argon fraction will change dramatically, which is very easy to cause nitrogen plug in the argon tower.
The main tower shall have strong anti disturbance ability, and the variable load regulation rate is limited, so it is not suitable to operate under extreme conditions. The heat exchange performance of main cooling shall be reliable, and the purity of oxygen and nitrogen products shall be reserved with adjustment allowance. Only when the main tower operates stably can it provide qualified feed gas for the argon tower and ensure the continuous and stable production of the oxygen, nitrogen and argon unit.

DEAR Air Separation Solve YourWhat are the requirements for the main column of the argon column of the air separation column?You can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
In the air separation refrigeration system, isentropic expansion and throttling expansion are two core cooling methods. The essential difference between the two determines the significant difference in refrigeration efficiency and application scenarios. Isentropic expansion is a process in which high-pressure gas drives the impeller to rotate through the expander and outputs shaft work to the outside. Under the ideal reversible condition, the entropy remains unchanged, that is, Δ s=0, and the internal energy is directly converted into mechanical work and removed from the system, so the cooling range is large and the cooling capacity is strong. There is a slight entropy increase in actual operation, which is close to the ideal degree measured by isentropic efficiency in engineering. Modern large and medium-sized air separation units use the isentropic expansion of the turbine expander as the main refrigeration source, and the expansion power can also be recovered for pressurization to f
2026.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top