Pressure pipe support hangers of large air separation unit
Pressure pipe support hangers of large air separation unit
The brackets are directly related to the safety of the piping and liquid air separation plant in the cold box during operation at low temperatures. Deformation or even damage to the piping due to bracket problems is often found during maintenance.
Products of Pressure pipe support hangers of large air separation unit
In the fertilizer industry, the air separation plant is mainly used for the production of nitrogenous fertilizer, accounting for 65-70% of the fertilizer structure in our country. The main raw material of chemical fertilizer is synthetic ammonia. The production and development direction of synthetic ammonia in our country mainly takes coal as raw material, adopts new coal gasification technology to build large-scale synthetic ammonia production enterprises, and eliminates small enterprises with high energy consumption and high pollution. In the production of synthetic ammonia
DEAR air separation has provided several sets of air separation equipment for the metallurgical industry for many years, and has accumulated rich experience. The equipment is operated safely and stably, adopting the whole low pressure process of molecular sieve adsorption and turbine expansion machine refrigeration
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower.
The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered.
The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
In the air separation refrigeration system, isentropic expansion and throttling expansion are two core cooling methods. The essential difference between the two determines the significant difference in refrigeration efficiency and application scenarios.
Isentropic expansion is a process in which high-pressure gas drives the impeller to rotate through the expander and outputs shaft work to the outside. Under the ideal reversible condition, the entropy remains unchanged, that is, Δ s=0, and the internal energy is directly converted into mechanical work and removed from the system, so the cooling range is large and the cooling capacity is strong. There is a slight entropy increase in actual operation, which is close to the ideal degree measured by isentropic efficiency in engineering. Modern large and medium-sized air separation units use the isentropic expansion of the turbine expander as the main refrigeration source, and the expansion power can also be recovered for pressurization to f