Home / All Air Separation tags /

Orifice plate head for small air separation units heat exchangers

Orifice plate head for small air separation units heat exchangers
A baffle plate with holes is pretended inside the air head. The plate effectively allows the inlet fluid to percolate and redistribute through micro-perforations, thus radically improving the problem of uneven distribution at the inlet of the heat exchanger, but different orifice plate structures still have different distribution effects.
Cases of Orifice plate head for small air separation units heat exchangers
More
News of Orifice plate head for small air separation units heat exchangers
More
Jul 29, 2020
On July 27, it was reported that the equipment delivery work of DEAR air separation for Tianyuan Chemical project has started successively. Since t
Jul 20, 2020
On July 20, it was reported that DEAR air separation held a brainstorming morning meeting of safety production. The meeting was presided over by Wang
Albums of Orifice plate head for small air separation units heat exchangers
More
Solutions of Orifice plate head for small air separation units heat exchangers
More
1500/100 Y-type solution for small air separation plant in new material industry
The new material industry system of our country has been initially formed and the development situation is good. With the introduction of national strategic planning such as "The development plan of national strategic emerging industries in the 13th Five-Year Plan" and "The development plan of new material industry in the 13th Five-Year PlanThe new material industry system of DEAR air separation has been initially formed and the development situation is good. With the introduction of national strategic planning such as "The development plan of national strategic emerging industries in the 13th Five-Years Plan" and "The development plan of new material industry in the 13th Five-Years Plan", it has created a good policy environment for the development of new material industry. Recently, DEAR air separation cooperated with clients on the 1500/100 Y-type project of small air separation plant. The overall design of the project is reasonable, and the one-time drive is successful, and all the
4500/4500-type solution for small and medium-sized air separation plant in nonferrous industry
According to the influence and reform of the general environment of the non-ferrous industry, the problems faced by this industry are becoming more and more serious, and the control of production capacity is particularly important. Recently, the 4500/4500 type small air separation equipment project signed with customers by DEAR Air Separation, through the trial run stage, all the technical indicators have reached or exceeded the design standard, and have been continuously sending nitrogen for several days, which has been well received by users.
Faq of Orifice plate head for small air separation units heat exchangers
More
Due to the age and disrepair of the small air separation unit, the cold box outside the pipeline and flange, valve connections have external leakage phenomenon. This part of the trace leakage for the normal operation of the small air separation unit is not significant, but for the gas tightness of the pressure test has a significant impact. Purified air, booster air.O2, N2, WN in and out of the cold box main exchange cold box flange is the internal thread connection method, not easy to disassemb...
May 19, 2022
The inspection work includes setting up scaffolding from bottom to top in the cold box and entering the cold box to check the specific damage to the piping. The liquid-air return pipe of the crude argon tower was bent and deformed, and the RTD cable on the liquid-air pipe was disconnected, and the safety valve pipe of the liquid-air steam of the crude argon tower was deformed and extruded together with the safety valve pipe of the condenser of the fine argon tower. The fine argon tower evaporato...
May 19, 2022
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top