What are the causes of icing on the outside of the incubator of air separation unit?

What are the causes of icing on the outside of the incubator of air separation unit?
Jul 16, 2026
Author: DEAR AST

The essence of external icing of air separation incubator is the leakage of local cooling capacity of the tank, and the water vapor in the external air condenses and freezes when it is cold. The main reasons are divided into five categories:
The box seal fails. The sealing gaskets of manholes, manholes and pipeline through plate interfaces are aging, bolts are loose, the box shell welds are cracked, and the external high humidity air continues to penetrate into the box. The moisture is cooled after contacting the low-temperature insulation material, and the cooling capacity is transmitted to the outer wall, and the water vapor is directly condensed and frozen.
The performance of insulation layer is deteriorated. The pearlite insulation material in the box is damped, hardened or insufficiently filled, and the insulation capacity is greatly reduced. The cold capacity of the low-temperature pipeline quickly penetrates the insulation layer and is transferred to the box shell; At the same time, there are holes in the insulation layer, forming a local cold bridge, causing freezing at fixed points on the outer wall.
Internal low temperature medium leakage. The low-temperature liquid oxygen, liquid nitrogen and the welds and valves of low-temperature process pipes in the box are damaged, and the low-temperature medium or cold air leaks out, which directly cools the steel plate of the box, causing rapid icing on the outer wall. This kind of icing is generally concentrated in scope and has a large ice thickness.
The gas seal system inside the box is abnormal. The dry nitrogen gas seal pressure of the incubator is insufficient, and the gas seal pipeline is blocked, which cannot isolate the invasion of external wet air; Negative pressure fluctuation of equipment operation further aggravates moisture backflow and accelerates frost and ice formation on the outer wall.
Impact of environmental conditions. In rainy season, high humidity and low temperature environment, the air moisture content is high, and the cold and heat exchange is intensified; Excessive temperature difference between day and night will also aggravate the condensation and freezing phenomenon on the outer wall of the box.

DEAR Air Separation Solve YourWhat are the causes of icing on the outside of the incubator of air separation unit?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top