Liquid air and liquid nitrogen supercooler uses nitrogen as cold source to cool liquid air or liquid nitrogen. There are Pipe type and plate type cooling device. When leakage occurs, it will affect the normal operation of the distillation column. It can be divided into two situations: 1) liquid air and liquid nitrogen leak to the nitrogen side. Since the liquid air leaks to the nitrogen side, it will be further recovered in the heat exchanger, so the increase of cold loss is not obvious, but the temperature at the cold end is Ding. Will drop, the cold end is too cold. If it is liquid leakage, because of the low concentration of nitrogen in liquid, the leak into the gas nitrogen will make the purity of gas nitrogen decline. After the leakage of liquid, the amount of liquid going into the tower will decrease and the recirculation fluid will decrease, which will worsen the rectifying working condition and decrease the oxygen output. In severe cases, the distillation tower will not work...