Why should leak testing of air separation equipment be strictly controlled?

Why should leak testing of air separation equipment be strictly controlled?
May 29, 2024
Author: DEAR AST

The compressor of an air separation plant consumes electrical energy and compresses both gases and liquids inside the plant to very low temperatures. The low temperature gases are -173°C for liquid air, -180°C for liquid oxygen and -177 to -193°C for liquid nitrogen.
Their coldness can be recycled in the heat exchanger. In the air separation plant pressure test leakage detection, to strictly control, if the pipeline, valve or even the local position of the equipment leakage, leakage of that part of the cryogenic gases or liquids of the cold can not be recovered, not only greatly increase the other cold loss, will also be in the cold preservation of the box inside and outside the condensation, icing, increasing the run cold loss. Leakage is often the more the development of the more serious, and finally reached the point of no control. This part of the cold loss in the design is not taken into account, to make up for this part of the cold loss, will destroy the normal work of the device, and even can not maintain production, forced to shut down. Liquid piping absolutely does not allow leakage. Liquid leakage and gas leakage, compared with the greater harm, because it is the unit of cold than the same temperature of the gas to be about twice as large, and the density of the liquid is hundreds of times that of the gas. If the leakage, the increase in the amount of cold loss accordingly need to increase the amount of expansion to make up for the air separation equipment can not work properly.
Therefore, strict air separation device pressure test to pick up leakage, to avoid causing significant losses.

DEAR Air Separation Solve YourWhy should leak testing of air separation equipment be strictly controlled?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the reason why gas nitrogen and liquid nitrogen are in coexistence at the top of an air separation tower?
2024.09.14
A user of DEAR air separation reflected that when the air separation plant was put into operation, a large liquid nitrogen storage tank was equipped for emergency backup when the air separation was stopped or export of liquid products. The value of oxygen content in nitrogen product is designed to be less than 3ppm (i.e., < 3 ×10-6) due to the high requirement of users for nitrogen purity. But in fact, the oxygen content of liquid nitrogen in the tanks had been found more than 5ppm. The substandard purity of liquid nitrogen not only affects the export of products, but also directly affects the emergency backup of liquid nitrogen backup system.
2024.09.13
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top