The main function of the pre cooling system is to cool the moist air after the air compressor is pressurized, and further wash the micro particle dust and some water-soluble substances (NH3) in the air Impurities such as SO2, etc. The air cooled by the air cooling tower is approximately saturated with humid air. According to the working characteristics of the purification system, the lower the temperature of the humid air exiting the air cooling tower, the lower the water content, which is more conducive to reducing the adsorption load of the purification system.
Working principle and process: The air cooling tower is divided into two sections. The lower section is cooled by circulating water, while the upper section is cooled by chilled water. Cooling water and chilled water are directly used to exchange heat with moist air on the loose packing to reduce the temperature of the humid air. Cooling water is introduced from the lower part of the air cooling tower, while chilled water is introduced from the upper part of the air cooling tower. The cooling water comes from the factory's cooling water supply network pool, which is pressurized by the cooling water pump and introduced. After heat exchange, it is collected at the bottom of the air cooling tower and returned to the cooling water return network. The chilled water comes from a circulating water pool and comes into contact with dry ammonia wastewater in the water-cooling tower. It uses the latent heat of water vaporization to achieve cooling, and then further lowers the temperature through an ammonia freezer. It is then pressurized and introduced into the chilled water pump. A water collector is installed at the top of the air cooling tower to separate the free water carried in the air.
DEAR Air Separation specializes in the research and development, manufacturing, and installation of various complete sets of air separation equipment, providing customers with efficient engineering and technical solutions.

DEAR Air Separation Solve YourWhat is the main function and working principle of the pre cooling system of the air separation equipment?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The liquid air separation plant system uses the cold energy to produce liquid oxygen, liquid nitrogen and liquid argon in an air separation system, including an air compression pre-cooling system, an air purification system, an air separation system and a nitrogen circulation system for liquid air separation plant cold recovery. the nitrogen circulation system for liquid air separation plant cold recovery is placed in a separate cold box from the main cold box of the air separation system. the l...
2026.08.03
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top