当前位置: Home / Faq / Liquefied air separation FAQ /

How to increase the output of oxygen?

How to increase the output of oxygen?
Jun 24, 2024
Author: DEAR AST
Question Reply

In addition to reducing air loss as much as possible, the factors that affect oxygen productionAir separation equipmentResistance to increase the air volume; reduce the loss of cold running, incomplete loss of heat exchange and leakage as much as possible to reduce the expansion of air volume, here mainly from the angle of adjusting the rectification working condition, analyze the method of adjusting output:


1) the liquid level should be stable. The stability of liquid oxygen level marks the cooling balance of the equipment. If the liquid oxygen level is high and low, it is very difficult to adjust the purity. Reasonably adjust the expansion amount and the opening degree of liquid-air and liquid-oxygen regulating valve to make the liquid-oxygen surface stable.


2) adjust the purity of liquid air and liquid nitrogen. Rectification in the lower tower is the foundation of the upper tower. The change of the amount of liquid nitrogen and liquid nitrogen will affect the purity of liquid nitrogen and the reflux ratio of the distillation section of the upper tower. If the amount of liquid nitrogen is too small, although the nitrogen purity is very high, but the recirculation liquid provided for the distillation section is too small, the purity of nitrogen will be reduced. At this time, due to the low oxygen concentration in the liquid, the purity of oxygen will decrease and the output of oxygen will decrease. Therefore, the best rectification working condition of the lower tower should be to increase the amount of extraction as much as possible under the condition that the purity of liquid nitrogen meets the requirements. On the one hand, it provides more recirculation fluid for the distillation section of the upper tower; on the other hand, it increases the oxygen concentration in the liquid and reduces the distillation burden of the upper tower, so that it is possible to increase the oxygen production. What needs to be explained here is that liquid nitrogen regulating valve should be used to adjust the purity of liquid nitrogen, instead of the liquid nitrogen return valve of the lower tower. The return valve should be fully open under normal circumstances.


3) adjust the rectification working condition of the upper tower, and strive to improve the average nitrogen purity. The average nitrogen purity marks the oxygen loss rate. And the average nitrogen purity depends on the purity of sewage nitrogen, because the amount of sewage nitrogen accounts for a large proportion. The purity of polluted nitrogen is also mainly guaranteed by providing the required liquid nitrogen from the lower tower. At present, the rectification working condition of the tower is normal while the purity of dirt and nitrogen is still too low, it may be due to the reduction of the rectification efficiency of the upper tower (for example, the tower block or leakage); or the expansion air volume is too large; or the amount of oxygen taken out is too small and the purity is too high, which will increase the amount of rising steam and decrease the reflux ratio. To improve the rectification working condition of the upper tower, it is mainly to control the amount of oxygen and nitrogen taken out. On the one hand, the amount of taking out the two should be appropriate; on the other hand, the valve opening degree should be moderate, so as to reduce the pressure of the upper tower as much as possible, which is beneficial to the rectification and improve the purity of the nitrogen.

DEAR Air Separation Solve YourHow to increase the output of oxygen?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Answer: select the small cryogenic air separation unit with argon, and give priority to verifying the real continuous operation performance of the unit with argon below 1000nm ³/h, avoiding the scheme with only drawings and no long-term operation record. Key dimensions of model selection: 1. operation performance: it is confirmed that the manufacturer has a long-term stable production case of small flow air separation with argon. Deere air separation small-scale hydrogen free total distillation argon extraction air separation, supports scale customization below 1000nm ³/h, and is equipped with intelligent control system, with mature landing performance. 2. power consumption per unit liquid argon
2026.11.06
Answer: the default unit gauge pressure is MPa (g), and the mainstream is cryogenic full low pressure external compression process. Design pressure of conventional energy-saving models in the industry: 0.50~0.55 MPa (g); The lower limit of stability of ordinary process is about 0.45 MPa (g). In general, it is not recommended to be lower than 0.42 MPa (g) for a long time in the conventional scheme. If the pressure is too low, there will be risks such as poor heat exchange in the precooling tower, insufficient purification of molecular sieve, difficult to balance the cooling capacity, and the air compressor close to the surge area. The internal compressed air is distributed with a booster. The main air compressor is mostly 0.55~0.65 MPa (g), and the lower limit is mostly 0.50 MPa (g), which is difficult to achieve below 0.45MPa (g). Deere air separation ultra-low discharge pressure patented energy-saving external compression air separation, through the collaborative optimization of the w
2026.11.06
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top