When the liquid passing capacity of the liquid-air regulating valve is not enough, what influence will it bring to the rectification working condition?

When the liquid passing capacity of the liquid-air regulating valve is not enough, what influence will it bring to the rectification working condition?
Jul 02, 2024
Author: DEAR AST
Question Reply

If the passing capacity of the liquid-air regulating valve selected in the design is too small, or when installing, it is related to liquid nitrogenControl valveWrong replacement, or blocking of regulating valve, liquid-air adsorber and supercooler during operation, all of them can reduce the passing capacity of liquid-air. Even if the regulating valve of the liquid level is opened to the maximum, the liquid level of the liquid level will continue to rise. In order to maintain the stability of the liquid level of the lower tower, we have to adopt the method of enlarging the liquid nitrogen regulating valve to reduce the reflux liquid of the lower tower, which will destroy the normal rectification working condition of the lower tower. Because the amount of liquid nitrogen is too large, the purity of liquid nitrogen decreases, and the purity of nitrogen in the upper tower also decreases, the extraction rate of oxygen decreases, and the output of oxygen decreases. At the same time, although the oxygen purity in the liquid air has been improved, the oxygen content in the liquid in the distillation section of the upper tower decreases due to the increase of reflux ratio. Therefore, the overall result still decreases the oxygen purity of the product.


When the above situations occur, the output and quality of oxygen often fail to reach the index, so measures must be taken according to the reasons. If the passing capacity of the valve is not enough, a bypass valve can be added. When the liquid-air pipeline system is seriously blocked and normal production cannot be maintained, it has to be stopped and heated.

DEAR Air Separation Solve YourWhen the liquid passing capacity of the liquid-air regulating valve is not enough, what influence will it bring to the rectification working condition?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The non-power consuming option for liquid air separation plants can be used for full liquid air separation plants,where the produced liquid is sold off. This approach is currently available for most LNG receiving stations. For air separation units with a large cold capacity, the liquid air can be pressurised to 6baA in a vacuum storage tank, and then heat exchanged through a heat exchanger, instead of the air compressor, directly into the cold box for distillation. At the same time in the cold b...
2026.03.13
1. Before connecting the pipe orifice of each container, clean white cloth shall be used to tie the orifice to prevent grease and dirt from entering. 2. When welding in the cold box and in the condensing evaporator, it is strictly forbidden for flame or arc to touch the surface of vessels and pipes. 3. The containers, valves, pipes and corresponding supports in the cold box, the surface of the cold box and the foundation surface shall not be stained with grease after installation, otherwise, degreasing treatment shall be carried out.
2026.03.12
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top