When the liquid passing capacity of the liquid-air regulating valve is not enough, what influence will it bring to the rectification working condition?

When the liquid passing capacity of the liquid-air regulating valve is not enough, what influence will it bring to the rectification working condition?
Jul 02, 2024
Author: DEAR AST
Question Reply

If the passing capacity of the liquid-air regulating valve selected in the design is too small, or when installing, it is related to liquid nitrogenControl valveWrong replacement, or blocking of regulating valve, liquid-air adsorber and supercooler during operation, all of them can reduce the passing capacity of liquid-air. Even if the regulating valve of the liquid level is opened to the maximum, the liquid level of the liquid level will continue to rise. In order to maintain the stability of the liquid level of the lower tower, we have to adopt the method of enlarging the liquid nitrogen regulating valve to reduce the reflux liquid of the lower tower, which will destroy the normal rectification working condition of the lower tower. Because the amount of liquid nitrogen is too large, the purity of liquid nitrogen decreases, and the purity of nitrogen in the upper tower also decreases, the extraction rate of oxygen decreases, and the output of oxygen decreases. At the same time, although the oxygen purity in the liquid air has been improved, the oxygen content in the liquid in the distillation section of the upper tower decreases due to the increase of reflux ratio. Therefore, the overall result still decreases the oxygen purity of the product.


When the above situations occur, the output and quality of oxygen often fail to reach the index, so measures must be taken according to the reasons. If the passing capacity of the valve is not enough, a bypass valve can be added. When the liquid-air pipeline system is seriously blocked and normal production cannot be maintained, it has to be stopped and heated.

DEAR Air Separation Solve YourWhen the liquid passing capacity of the liquid-air regulating valve is not enough, what influence will it bring to the rectification working condition?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top