当前位置: Home / Faq / Liquefied air separation FAQ /

Liquid Air Separation Plant Cold Energy Utilization  Features

Liquid Air Separation Plant Cold Energy Utilization  Features
Apr 07, 2022
Author: DEAR AST

The liquid air separation plant system uses the cold energy to produce liquid oxygen, liquid nitrogen and liquid argon in an air separation system, including an air compression pre-cooling system, an air purification system, an air separation system and a nitrogen circulation system for liquid air separation plant cold recovery. the nitrogen circulation system for liquid air separation plant cold recovery is placed in a separate cold box from the main cold box of the air separation system. the liquid air separation plant cold recovery system includes a high and low pressure low temperature circulation nitrogen compressor, a high pressure heat exchanger, a gas-liquid separator and a nitrogen circulation system for liquid air separation plant cold recovery. high pressure heat exchanger, and gas-liquid separator. The raw air recovers the low temperature cold energy from the liquid air separation plant and transfers it to the air separation system. The high temperature cold energy is used for the intermediate cooling of the air compressor and the cooling of the compressed air by means of a suitable refrigerant. Utilising the liquid air separation plant cold energy in stages significantly reduces electricity and water consumption compared to conventional all-liquid air separation plants. Leakage of methane into the fractionation system is eliminated, making the liquid air separation plant  safe.

Kaifeng DEAR Air Separation Co., Ltd. has achieved fine, perfect, strict and safe design in terms of material selection for small air separation units, large air separation units and liquid air separation plant manufacturing according to actual requirements and specific conditions.

山东钢铁集团(壶井)16000

DEAR Air Separation Solve YourLiquid Air Separation Plant Cold Energy Utilization  FeaturesYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
When there is no pressure signal input, the valve is closed; when there is a pressure signal, the valve starts to open, and the larger the input signal, the larger the valve opening, this kind of film regulating valve is called air-opening film regulating valve in small air spearation unit. When there is no pressure signal input, the valve is fully open, and when there is a pressure signal input, the valve starts to close; the larger the input signal, the smaller the valve opening; when the inp...
2026.07.29
What is the cause of ultra low temperature in air separation plant and the principle of refrigeration equipment?
2026.07.28
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top