What are the requirements for the start-up and operation of liquid air separation plants?    

What are the requirements for the start-up and operation of liquid air separation plants?    
Apr 24, 2022
Author: DEAR AST

The start-up and operation of liquid air separation plants requires the operator to be familiar with the performance and operation of the systems, machines and equipment in the liquid air separation plants, to be familiar with the process flow diagram of the liquid air separation plants, and to master the operation rules and operating characteristics of the liquid air separation plants. In order to ensure the purity of the product, the operator must be able to improve the quality of the product and reduce energy consumption and costs. The staff must consider all systems in the liquid air separation plants as a whole.

The operation of liquid air separation plants consists of two parts.

(1) the commissioning of liquid air separation plants, i.e. the test, adjustment, blowing, etc., prior to the operation of the complete set of equipment linkage, the test is to ensure that each ministry, each system and its interconnection between the correct.

(2) The start-up of liquid air separation plants and put into normal operation. The commissioning of liquid air separation plants is after the installation or overhaul of liquid air separation plants, in the formal production before, the individual parts of the machine, equipment and complete sets of liquid air separation plants for a comprehensive pressure test, leak detection, adjustment, blowing and low-temperature bare cold test, etc.. The inspection of the installation or overhaul of air separation equipment includes checking the sealing performance and compensation performance after cold deformation at low temperatures, possible defects and installation defects in equipment and piping flow paths.

In order to ensure the safe, reliable, stable and high-quality continuous operation of the air separation equipment, Dear has developed detailed operating instructions for the complete set of small air separation units,large air separation units and liquid air separation plants.缅甸钢铁公司-1500

DEAR Air Separation Solve YourWhat are the requirements for the start-up and operation of liquid air separation plants?    You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the air separation plant, the main heat exchanger is the key equipment to ensure the performance of the whole set of equipment. The function of the main heat exchanger in the molecular sieve pre purification process air separation equipment is to ensure the temperature difference at the hot end to be kept at the design value by recovering the cold quantity of the backflow gas, provide sufficient expander gas to expander, make up for the cold quantity loss of the equipment, and provide the raw gas under the design condition for the lower tower.
2024.05.10
The air contains 0.932% of argon. When the upper tower wants to produce 99.6% of oxygen, it must contain 1.05% of argon in the nitrogen exhaust. From the perspective of the separation process, the stripping section (below the liquid-air inlet) in the upper column is basically an oxygen-argon separation, and the rectification section (above the liquid-air inlet) is basically a nitrogen-oxygen (argon) separation. . The boiling points of argon and oxygen are relatively close (the boiling point of o...
2024.05.08
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top