Selection of the illumination method for testing valves for oxygen in liquid air separation plants

Selection of the illumination method for testing valves for oxygen in liquid air separation plants
Apr 25, 2022
Author: DEAR AST

According to the shape, size, location and protection conditions of the cast steel parts, choose the appropriate transmission method. In the case of implementation should be given priority to single-wall transillumination, in the single-wall transillumination can not be implemented before allowing the use of double-wall transillumination method. In practice, single-wall external transmission method, internal transmission eccentric method, internal transmission centre method, double-wall transmission method is usually used for liquid air separation plant valve inspection.

When the internal diameter of the cast steel part is large, the internal penetration centre or internal penetration eccentric method is used.

When the bore diameter of the smaller cast steel parts using double-wall transillumination, and at least once in each of the two mutually perpendicular direction transillumination.

 Cast steel parts variable cross-sectional transillumination technical measures

 Double film technology

When the thickness of the workpiece varies greatly and two films with different sensitivities are used, the film with the higher sensitivity should be suitable for the transillumination of the thicker part of the workpiece and the film with the lower sensitivity should be suitable for the transillumination of the smaller part of the thickness of the workpiece. When the thickness of the workpiece does not vary considerably and two films of the same sensitivity are used, a single film should be used to evaluate the area of small thickness, and two films should be used to evaluate the area of large thickness when superimposed.

 Appropriate increase in transmittance voltage technique

For liquid air separation plant valve cross-sectional thickness changes are relatively small, especially when the cross-sectional thickness is continuously changing, can be used to appropriately increase the transillumination voltage technology for transillumination, improve the thickness tolerance.

Compensation techniques

For liquid air separation plant valve cross-sectional thickness variations or shaped workpieces, compensation technology should be used for transillumination.

By using the above technical measures, Dear Air Separation can ensure the quality of the valve body radiographic inspection negatives, thus ensuring the small air separation units, large air separation units and liquid air separation plants detection rate of valve body casting defects.

梅花项目2

 

DEAR Air Separation Solve YourSelection of the illumination method for testing valves for oxygen in liquid air separation plantsYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top