Why does the moisture content of air in a small air separation unit decrease after passing through a cooling tower?

Why does the moisture content of air in a small air separation unit decrease after passing through a cooling tower?
Apr 24, 2022
Author: DEAR AST

The main functions of the air cooling tower: heat exchange, washing and buffering.

In low-pressure small air separation unit, the absolute pressure of the compressed air discharged from the air compressor is around 0.6 MPa. After the air is compressed, the water content per unit volume increases so that its moisture content reaches the saturation content corresponding to the prevailing temperature. When the air flows through the air cooling tower, as the temperature decreases, the corresponding saturated moisture content decreases, and the excess will be precipitated from the gas in a liquid state. This part of the water vapour condensation into water, while releasing latent heat of condensation, cooling water increases, the water temperature will also rise, but the air out of the tower temperature is reduced. Therefore, the air in the cooling tower, although the air is in direct contact with water, but the moisture content will be reduced.

Dear has extensive practical experience in researching the technical principles of equipment manufacture and process systems, and the small air separation unit is installed to high quality requirements.

缅甸1500空分冷箱

 

 

DEAR Air Separation Solve YourWhy does the moisture content of air in a small air separation unit decrease after passing through a cooling tower?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top