When the whole low pressure oxygen generator encounters emergency power failure, the first task is to open the air release valve at the end of the air compressor and close the valve of air entering the distillation tower quickly, in case of the air compressor's outlet check valve failure, which causes compressed air to reverse and causes the air compressor to reverse and burn out the bearing. Then it can be conducted according to the following steps: 1) change the switching mechanism from automatic to manual, and close the forced Valve and average pressure switching valve of air entering the tower. Open the sewage nitrogen vent valve. 2) cut off the solenoid valve of the expansion machine, and close the inlet regulating valve of the expansion machine and the inlet and outlet valves of the expansion machine. 3) close the regulating valve of liquid, liquid nitrogen and sewage nitrogen. 4) turn off all the oxygen and nitrogen products and send them out of the valve, and open the vent v...
Sep 19, 2022