Reasons for the decrease in moisture content of air after passing through the cooling tower of an air separation plant

Reasons for the decrease in moisture content of air after passing through the cooling tower of an air separation plant
May 08, 2023
Author: DEAR AST

For low-pressure air separation devices, the absolute pressure of compressed air discharged from the air compressor is around 0.6MPa. After compression, the moisture content per unit volume of air increases, causing its moisture content to reach the saturation level corresponding to the temperature at that time. When air flows through the air cooling tower, as the temperature decreases, the corresponding saturated moisture content decreases, and the excess part will precipitate from the gas in a liquid state. This portion of water vapor condenses into water, while releasing latent heat of condensation, which not only increases the cooling water volume but also increases the water temperature. But the temperature of the air exiting the tower decreases, so although the air comes into direct contact with water in the cooling tower, its moisture content will actually decrease.

The research and development of DEAR Air Separation has always focused on intelligent air separation devices and the development of new energy-saving products. Through cooperation with renowned universities and research institutions both inside and outside the province, and through independent and collaborative innovation, a group of professional engineering and technical teams have been cultivated, and a number of high-tech gas separation device research and development projects have been stored.

DEAR Air Separation Solve YourReasons for the decrease in moisture content of air after passing through the cooling tower of an air separation plantYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
1. Before filling with pearlite, the water accumulated on the foundation surface of air separation unit must be removed, dried with hot air, and all manholes shall be closed. 2. When filling pearlite, all containers and pipes in the cold box should be inflated and kept at 50kPa pressure, then slightly open the valve of each meter pipeline, and all thermometers should be electrified to check whether the thermometer cable is damaged during the filling process. 3. The filled pearlite shall not be mixed with combustibles. 4. When filling with pearlite, coarse mesh or pearlite pouring device should be set at the manhole on the top of the cold box to prevent whole bag pearlite from entering the cold box. 5. After the pearlite is filled, the manhole shall be sealed.
2026.08.18
What is the oxygen extraction rate?
2026.08.17
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top