How to carry out pressure testing and leak detection of air separation equipment

How to carry out pressure testing and leak detection of air separation equipment
Jun 19, 2023
Author: DEAR AST

Pressure testing and leak detection are both air tightness checks of air separation equipment. Its purpose is to examine the quality of installation, piping, and welding.

There are two types of pressure testing for air separation equipment: one is strength pressure testing, which tests the safety of the equipment. Generally, individual equipment is tested at the manufacturing plant or before installation upon arrival at the site. The second is the airtightness test, with the purpose of detecting leaks. Generally, the whole system pressure test of air separation equipment during installation refers to the latter. The pressure level and test method of the airtightness test vary depending on the object being tested, and should be carried out in accordance with the technical documents of the manufacturer. After the installation of general air separation equipment, a full system pressure test is required and the residual rate is calculated. The requirement for residual rate to be above 95% is qualified.

DEAR Air Separation is a manufacturer specializing in the research and development, manufacturing, and installation of various complete sets of air separation equipment. We conduct in-depth analysis and research on air separation equipment technology, continuously expanding our professional technical team, and providing customers with high-quality air separation industry solutions in air separation equipment construction projects.

DEAR Air Separation Solve YourHow to carry out pressure testing and leak detection of air separation equipmentYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What issues should be paid attention to during pressure testing of air separation equipment
2026.02.27
Liquid air separation plant liquid hub area piping arrangement is mainly oxygen, nitrogen, argon liquid pipeline and pump box in the liquid pipeline arrangement. As oxygen, nitrogen, argon liquid temperature is extremely low (liquid oxygen -183 ° C ℃, liquid nitrogen -196 ° C, argon liquid -185.7C), in the liquid flow process, resulting in a certain amount of gasification, piping should pay attention to the slope of the liquid pipeline towards (no slope requirements on the process). In ...
2026.02.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top