Engineering Design of DCS System for Liquid Air Separation Plant
Engineering Design of DCS System for Liquid Air Separation Plant
The dcs system design includes grounding methods, grounding requirements, signal shielding, and grounding electrode selection. The reliable grounding of dcs is the primary condition to ensure the safe and stable operation of the control system.
Products of Engineering Design of DCS System for Liquid Air Separation Plant
Chemical industry has the characteristics of large scale, long industrial chain and so on. It is the basic industry and an important part of Chinese national economy. In recent years, environmental protection has been paid more and more attention, and the green development of chemical industry is also very important. In addition, the chemical industry in the industrial integration, scientific and technological innovation is also in constant efforts to advance. DEAR air separation helps the chemical industry to transform and upgrade to be environmental-friendly. DEAR’s large-scale air separation plant KDON (Ar) - 18000 / 36000-600 can use ultra-low pressure discharge energy-saving air separation technology patent, which can reduce the energy consumption of equipment operation by 5% - 15% and save a lot of production costs.
DEAR air separation has cooperated with customers in metallurgical industry domestic and abroad in many projects, and has rich project experience. DEAR has continuously invested in the research and development of large-scale air separation plant. In view of metallurgical industry, DEAR combined with the characteristic of this industry, develops high-efficiency energy-saving air separation plant, to meet the needs of large and medium customers. DEAR air separation uses the rapid development of internet technology to establish a remote monitoring system to collect real-time operation data of each air separation plant, and provides the best suggestions for users by using big data analysis.
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side.
When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti