What factors will affect the displacement of centrifugal compressor?

What factors will affect the displacement of centrifugal compressor?
Jun 16, 2023
Author: DEAR AST
Question Reply

Impact centrifugal typeCompressorThere are many factors of gas discharge, except that it is related to design, manufacture and installationCompressorThe main factors that can affect the gas discharge in operation are:
1) the air filter is blocked or the resistance increases, which causes the pressure of the compressor's suction to decrease. When the outlet pressure remains unchanged, makeCompressorThe pressure ratio increases. According to the performance curve of the compressor, when the pressure ratio increases, the displacement will decrease;
2) Air separation equipmentPipeline blocking, resistance increase or valve failure, cause air compressor exhaust pressure rise. Under the condition of constant suction pressure, the pressure ratio increases, resulting in the reduction of exhaust volume;
3)CompressorThe blocking of intermediate cooler or the increase of resistance will cause the reduction of exhaust volume. However, the situation of blocking in different positions is different: if the gas side resistance of the cooler increases, only the internal resistance of the machine will be increased, which will reduce the efficiency of the compressor and the exhaust volume; if the water side resistance increases, the circulating cooling water will decrease, which will make the gas cooling bad, thus affecting the next level of inhaling, makingCompressorThe reduction of exhaust volume;
4) bad sealing causes gas leakage. Including: ① internal leakage, that is, the air running between levels. Reverse the compressed gas, and then conduct the second compression. It will affect the working condition at all levels, increase the low pressure grade ratio and decrease the high pressure grade ratio, which will make the whole compressor deviate from the design working condition and reduce the displacement; ② external leakage, that is, air leakage from the shaft seal to the outer shell. Although the amount of absorption remains unchanged, a part of the compressed gas leaks out, which naturally causes the reduction of exhaust volume;
5) cooler leakage. If the first level leakage, because the water side pressure is higher than the gas side pressure, the cooling water will enter the air side channel, and will be further carried into the impeller and the diffuser by the airflow. After a certain period of time, it will cause scaling and blocking, which will reduce the air flow. If the second and third level cooler leaks, because the pressure of the air side is higher than that of the water side, the compressed air will leak into the cooling water and run away, which will reduce the displacement;
6) the decrease of the frequency or voltage of the power grid causes the motor andCompressorReduction of rotation speed and reduction of exhaust volume;
7) when the temperature of any primary suction increases and the density of gas decreases, it will also lead to the reduction of suction.

DEAR Air Separation Solve YourWhat factors will affect the displacement of centrifugal compressor?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
In the air separation refrigeration system, isentropic expansion and throttling expansion are two core cooling methods. The essential difference between the two determines the significant difference in refrigeration efficiency and application scenarios. Isentropic expansion is a process in which high-pressure gas drives the impeller to rotate through the expander and outputs shaft work to the outside. Under the ideal reversible condition, the entropy remains unchanged, that is, Δ s=0, and the internal energy is directly converted into mechanical work and removed from the system, so the cooling range is large and the cooling capacity is strong. There is a slight entropy increase in actual operation, which is close to the ideal degree measured by isentropic efficiency in engineering. Modern large and medium-sized air separation units use the isentropic expansion of the turbine expander as the main refrigeration source, and the expansion power can also be recovered for pressurization to f
2026.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top