How does the nitrogen in the water cooling tower cool the water?

How does the nitrogen in the water cooling tower cool the water?
Apr 18, 2023
Author: DEAR AST
Question Reply

Water cooling towerIt is a hybrid heat exchanger. The relatively high temperature cooling water (about 35℃) from the air cooling tower flows down from the top spray, and the relatively low temperature sewage nitrogen (about 27℃-27℃) from the switching heat exchanger) the bottom-up flow, the direct contact between the two, not only heat transfer but also mass transfer, is a relatively complex heat transfer process. On the one hand, because the temperature of water is higher than that of sewage nitrogen, there is heat which is directly transmitted from water to sewage nitrogen to cool it down; on the other hand, due to the relatively dry sewage nitrogen, the relative humidity is only about 30%, therefore, the molecules of water can continuously evaporate and spread into the dirt and nitrogen. However, the evaporation of water needs to absorb the latent heat of vaporization. Taking away the heat from the water makes the temperature of the water lower continuously. This phenomenon is like putting a cup of hot boiled water in the air to cool down. Hot boiled water contacts with the air. On one hand, it transmits heat directly (or through the container wall) to the air, on the other hand, it steams, steam and spread the molecules of water into the air to take away the heat (latent heat of vaporization), making the hot boiled water cool down continuously. It must be pointed out that the moisture absorption of sewage nitrogen is the main factor to cool the water, so the relative humidity of sewage nitrogen is the key to influence the cooling effect. This is also the reason why the outlet temperature of cooling water may be lower than the inlet temperature of sewage nitrogen.

DEAR Air Separation Solve YourHow does the nitrogen in the water cooling tower cool the water?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Water evaporation, wind-blown losses and other situations occurring in industrial circulating cooling water system operation, resulting in the continuous concentration of circulating water, then the salts contained therein exceed the standard, anions and cations increase, PH value changes significantly, resulting in the deterioration of water quality. The temperature of the circulating water rises and the PH value and nutrients increase, which is conducive to the reproduction of microorganisms. ...
2026.06.03
If the temperature after the expander of the air separation unit is too low, it should find out the cause of the low temperature and take measures to increase the temperature after the expander. If the low temperature of expander is caused by liquid air in front of expander, appropriate measures should be taken to reduce the liquid air level of lower column. If it is caused by other reasons, the more effective method is generally throttling in front of the expander. Throttling will not increase the temperature in front of the expander, but throttling will reduce the pressure in front of the expander, so the pressure difference between the front and the back of the expander will be reduced, the expander will do less work and the temperature will be reduced, so the temperature at the after of the expander can be increased.
2026.06.01
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top