What are the characteristics of steam heating and electric heating equipment for the heating and regeneration of molecular sieve purifier, and what problems should be paid attention to in the regenera

What are the characteristics of steam heating and electric heating equipment for the heating and regeneration of molecular sieve purifier, and what problems should be paid attention to in the regenera
Apr 17, 2023
Author: DEAR AST
Question Reply

Steam heaterIt uses overheated water vapor as the heat source, so it is easy to leak and pollute the heating medium in the process of use, so the manufacturing requirement is strict,EquipmentThe cost is also relatively high; using steam for heating is cheaper than electricity, but it needs antifreezing treatment in winter. From the perspective of operation, electric heating will not affect the regeneration of the adsorber due to steam leakage, so the cost of the equipment is relatively low.

Molecular sieve purifierWhether steam or electric heating is used for heating and regeneration is related to equipment capacity and factory conditions. Generally, if the equipment capacity is relatively large and the factory has sufficient steam source, steam heating is usually adopted; if the equipment capacity is relatively small and the factory has difficulty in steam source, electric heating is adopted. Some also adopt steam heating first and then electric heating. Generally in normal production, steam heater is used for heating. When the steam pressure is insufficient or the molecular sieve needs to be activated, the electric heater should be put into use to increase the temperature of the heating medium.

The following problems should be paid attention to in regeneration operation:

1) no matter which kind of heating method, you should pay attention to the change of temperature curve of heating and cold blowing during the regeneration process of the adsorber. Description of abnormal changes of temperature curve:

① The regeneration heat source (steam or electricity) is insufficient or the gas volume is insufficient;

② If there is any change in the load of adsorber (especially the adsorptive water volume), the reason should be found out;

2) pay attention to the pressure change when the adsorber regenerates. If the pressure rises, it means that the resistance of the adsorber increases or the inlet and outlet valves of the adsorber are not closed tightly, the reason should be found out;

3) pay attention to the change of heating time. The extension of heating time should find out whether it is the heat source problem or the influence of the increased load of the adsorber;

4) note when operating the steam heater:

① Check the liquid level of condensate of steam heater frequently. High water level will affect the temperature of heat exchange;

② When the steam heat exchanger leaks, it will affect the effect of heating regeneration. Therefore, the moisture content of the gas after heat transfer should be checked frequently. Generally, the moisture content should be less than 1 × 10-6(Dew point temperature-65℃ ). Otherwise, check the working condition of the heat exchanger and handle it. There is usually a dew point detector behind the heater, and the change of dew point should be paid attention;

5) when using the electric heater, pay attention to that the heating medium flow should not be less than the requirement of process flow, otherwise the burning accident will occur. During cold blowing, pay attention to check whether the power supply has been cut off to prevent the electric heating components from burning out.

DEAR Air Separation Solve YourWhat are the characteristics of steam heating and electric heating equipment for the heating and regeneration of molecular sieve purifier, and what problems should be paid attention to in the regeneraYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What precautions should be taken when designing a complete set of air separation equipment?
2024.11.22
In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:   First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;   Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be man...
2024.11.21
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top