What should be paid attention to when filling cold insulation materials in air separation equipment

What should be paid attention to when filling cold insulation materials in air separation equipment
Apr 13, 2023
Author: DEAR AST

When filling cold insulation materials in air separation equipment, the following issues should be noted:

1) Before filling, the moisture on the foundation of the cold insulation box should be dried;

2) When filling, all equipment and pipelines inside the air separation equipment should be inflated with an inflation pressure of 0.045 0.05MPa, and the valves of each gauge pipe should be slightly opened for ventilation. Simultaneously energize each platinum resistor and monitor whether the meter tube and cable are malfunctioning at any time;

3) Be careful not to mix combustible materials or get damp inside the cold insulation materials;

4) Not suitable for filling in rainy or snowy days;

5) The filling should be dense and there should be no empty space. When filling slag cotton, it should be compacted layer by layer with a wooden hammer or round headed wooden stick, and its density should be checked by sampling in the manhole;

6) Construction personnel who load cold insulation materials should take labor protection measures and pay attention to personal safety, and add iron bars at the filling port; 7) When the cold insulation material sinks after driving, attention should be paid to supplementing it.

DEAR Air Separation is a manufacturer specializing in the research and development, manufacturing, and installation of various complete sets of air separation equipment. We conduct in-depth analysis and research on air separation equipment technology to provide customers with the most competitive air separation project design solutions.

DEAR Air Separation Solve YourWhat should be paid attention to when filling cold insulation materials in air separation equipmentYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
According to the daily water quality analysis and laboratory results, supplement the discharge water and control the dosing amount to make it reach the required data index. When the turbidity is >20mgL, increase the amount of drainage water, increase the flow of side filtration, and supplement clean water. According to the current situation of the circulating water system, try to increase the concentration multiple operation to save water and medicine. If the concentration multiplier is g...
2026.09.04
Before the air cooling columnand water cooling columnare hoisted in place, the anchor hole shall be cleaned, and there shall be no water and debris in the anchor hole.   After the air cooling columnand water cooling columnare hoisted in place, the perpendicularity of the equipment shall be checked. The perpendicularity shall be ≤ 1/1000 and the total length shall not exceed 10mm.   The bottom of the anchor bolt shall not touch the bottom of the reserved anchor hole. Af...
2026.09.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top