What issues should be paid attention to during pressure testing of air separation equipment

What issues should be paid attention to during pressure testing of air separation equipment
Feb 27, 2026
Author: DEAR AST

The main purpose of conducting air pressure tests on site for air separation equipment is to check the airtightness of the equipment. The following issues should be noted during pressure testing:

1) It is strictly prohibited to use oxygen as the pressure testing gas source;

2) For non degreasing equipment after pressure testing, clean and oil-free pressure testing air sources should be used;

3) The pressure gauge used for pressure testing should be calibrated and sealed with lead before use. Before pressure testing, carefully check whether the pressure gauge valve has been opened;

4) During pressure testing, it is not allowed to strike the pressure testing container with a hammer;

5) During pressure testing, screws cannot be disassembled or tightened;

6) When using a nitrogen gas cylinder or a higher pressure source to inflate a lower pressure container for pressure testing, a pressure reducing valve should be installed and direct inflation is strictly prohibited.

7) After the pressure test inflation reaches the specified pressure, the inflation pipe joint should be removed.

Whether it is equipment installation or debugging, DEAR Air Separation can provide comprehensive support to customers. A technical service team composed of experienced and skilled debugging experts is active in many regions and continuously receives technical skills training to meet customer needs. The debugging and installation methods are systematic and require strict checklists and protocols to meet standard delivery requirements, ensuring that the equipment can be assembled, integrated, and optimized correctly on site.

DEAR Air Separation Solve YourWhat issues should be paid attention to during pressure testing of air separation equipmentYou can also learn about otherHigh purity nitrogen air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top