Why does the liquid air level and liquid oxygen level rise when the air separation equipment is temporarily stopped

Why does the liquid air level and liquid oxygen level rise when the air separation equipment is temporarily stopped
Apr 12, 2023
Author: DEAR AST

During normal operation, the rising steam has a certain speed when passing through the small hole, which can hold the liquid on the fractionator tray, prevent the liquid from leaking from the small hole, and can only flow along the tray, and then flow to the next tray through the overflow bucket. After parking, due to the interruption of the rising steam, the liquid on the tray loses the support of the rising steam and flows sequentially from the sieve holes of each tray to the bottom, accumulating in the condensate evaporator and liquid kettle. Therefore, during temporary parking, the liquid oxygen and liquid air levels will rise, even exceeding the position of the expansion air and oxygen outlet pipe, which can easily cause accidents of expansion machine carrying liquid or switching heat exchanger cold end carrying liquid during restarting.

Therefore, when temporarily stopping the air separation equipment, attention should be paid to the liquid level position, and if necessary, some liquid can be discharged.

Over the years of operation, DEAR Air Separation has not only been committed to providing high-quality complete sets of air separation equipment to domestic and international customers, but also long-term services such as air separation equipment maintenance, energy conservation, intelligent upgrading and transformation. As of now, the company has undertaken the maintenance business of over 100 sets of air separation equipment, and has completed energy-saving and intelligent transformation of multiple sets of air separation equipment.

DEAR Air Separation Solve YourWhy does the liquid air level and liquid oxygen level rise when the air separation equipment is temporarily stoppedYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The comprehensive energy-saving transformation of cryogenic air separation is not a single point of equipment replacement, but a collaborative optimization of the whole system, which mainly covers six technical sectors: 1. optimization of compressed air supply system: frequency conversion/permanent magnet transformation of air compressor, matching of air supply pressure, reducing the loss of venting and depressurization, solving the problem of "big horse pulling small car", and the compression link accounts for more than 70% of the total energy consumption of air separation, which is the focus of energy conservation; 2. transformation of precooling and purification system: high efficiency and low resistance molecular sieve, adaptive regeneration control, air inlet precooling, reduce regeneration energy consumption and system resistance, and reduce compressor load; 3. upgrading of rectification and main heat exchange system: efficient and regular packing, optimization of reflux ratio, o
2026.11.20
Answer:>>the conventional air separation unit of DEAR air separation plant is designed for 20 years, which meets the design service life recommended by national standards and specifications, and is also the cost-effective optimization scheme for bot/boo gas investment and long-term stable gas consumption projects. The default recommended design service life of the national standard and relevant specifications, feasibility study, bidding and preliminary design drawings of pressure vessels is 20 years. Designed for 20 years: the cold box plate, heat exchanger and pressure bearing parts are of higher material selection grade, suitable for long-term continuous operation, and suitable for bot/boo gas investment, metallurgy and chemical industry long-term gas supply projects; The maintenance is in place and the technical transformation is timely. The actual stable service can reach 20-25 years, and the working condition management can reach 28-30 years. 15 years of design: moderate investmen
2026.11.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top