Why does the liquid air level and liquid oxygen level rise when the air separation equipment is temporarily stopped

Why does the liquid air level and liquid oxygen level rise when the air separation equipment is temporarily stopped
Apr 12, 2023
Author: DEAR AST

During normal operation, the rising steam has a certain speed when passing through the small hole, which can hold the liquid on the fractionator tray, prevent the liquid from leaking from the small hole, and can only flow along the tray, and then flow to the next tray through the overflow bucket. After parking, due to the interruption of the rising steam, the liquid on the tray loses the support of the rising steam and flows sequentially from the sieve holes of each tray to the bottom, accumulating in the condensate evaporator and liquid kettle. Therefore, during temporary parking, the liquid oxygen and liquid air levels will rise, even exceeding the position of the expansion air and oxygen outlet pipe, which can easily cause accidents of expansion machine carrying liquid or switching heat exchanger cold end carrying liquid during restarting.

Therefore, when temporarily stopping the air separation equipment, attention should be paid to the liquid level position, and if necessary, some liquid can be discharged.

Over the years of operation, DEAR Air Separation has not only been committed to providing high-quality complete sets of air separation equipment to domestic and international customers, but also long-term services such as air separation equipment maintenance, energy conservation, intelligent upgrading and transformation. As of now, the company has undertaken the maintenance business of over 100 sets of air separation equipment, and has completed energy-saving and intelligent transformation of multiple sets of air separation equipment.

DEAR Air Separation Solve YourWhy does the liquid air level and liquid oxygen level rise when the air separation equipment is temporarily stoppedYou can also learn about otherLarge air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top