Cause and elimination method of oil leakage failure of air compressor of air separation plant: There are three types of common failures in the use of air compressor: oil leakage failure, overheating failure and abnormal sound failure, which are analyzed and solved by classification below. Failure phenomenon: in the daily operation of the air compressor, the oil leakage phenomenon of the air compressor often occurs, and lubricating oil overflows outside. Cause of failure: 1. Oil seal falls off or oil seal defects leak oil. 2. The loose and open main shaft causes oil seal leakage. 3. The joint surface leaks, and the inlet and return oil pipe joints are loose. 4. If the belt is installed too tightly, the bearing bush will be worn. 5. Casting or processing defects can also cause oil leakage of the air compressor. Exclusion method: 1. When the air compressor leaks oil, pay attention to observing the oil seal position, and check whether the oil seal is cracked, and whether the inner lip i...
Sep 21, 2023
The flow integrator is used together with the flow meter and accumulates the total amount of fluid flowing through the pipeline within a certain period of time. The usage of the integrator is as follows: 1) calculate the integrator constant K. The meaning of K is the traffic value represented by each word (unit count) of the integrator. K = qv, max/R in the formula qv, max -- the maximum scale of the flow meter matched with the integrator; R -- when the input flow is qv, max, the number of words passed by the integrator within 1 hour is called integrator constant. 2) calculate the traffic. In a certain time interval, the difference of two reading times of the integrator multiplies the integral constant K, which is the total flow during this period of time. Use the formula to express: qv = (R2-R1) K in the formula K -- integral constant: R1 -- the first reading of the integrator; R2 -- the second reading of the integrator. For example, when the maximum scale of the flow meter used by...
Sep 13, 2023
When is the appropriate time for the expansion air to be sent to the tower during the start-up phase of the sub equipment
Sep 05, 2023
The running cycle of small-sized air separation plant is shorter than that of large-sized air separation plant, which is because small-sized air separation plant has no thorough removal of impurities than large-sized air separation plant. Therefore, in order to prolong the running cycle of the air separation Tower, we must start from the problem of removing moisture, carbon dioxide and grease: 1) most of the moisture in the air is collected during the compression and cooling process of the air compressor, remove in the oil-water separator, and absorb a small amount in the dryer (or purifier. If the amount of water entering the purifier increases, its cleaning load will increase, and the service life will be shortened, and the amount of water brought into the tower will increase. Therefore, it is very important to blow off oil-water separators at all levels correctly regularly. The water content in the compressed air is related to the temperature. Therefore, the cooling effect of the...
Aug 28, 2023
After removing the micro metal particles and dust impurities in the air through the air filter, the air enters the svk20-3s type turbine air compressor for 1-3 level compression and cooling to obtain 0. 5MPa normal temperature pressure gas. The liquid nitrogen on the top of the lower tower enters the top of the upper tower as the reflux fluid through the HV-l liquid nitrogen regulating valve after further condensation through the cooler; after the other one passes through the cooler, in front of the HV-1 valve, through the liquid nitrogen liquid level regulating valve, LCv-704 the condensing evaporator of the pure argon Tower as the cold source.
Aug 18, 2023
Shaft seal of centrifugal pump
Aug 09, 2023
How much argon fraction can the air separation tower extract when producing argon? What are its limitations?
Aug 01, 2023
What requirements should be met before the cold test of the inner fractionation pipeline and expander of the air separation unit
Jul 24, 2023
How to operate cold start-up aFfter fault shutdown of air separation unit
Jul 14, 2023
Why did the resistance gauge at the lower part of the upper tower indicate before the main cold liquid level of the air separation equipment appeared
Jul 06, 2023
How to perform bare cooling on air separation equipment and what work needs to be done after bare cooling
Jun 28, 2023
How to carry out pressure testing and leak detection of air separation equipment
Jun 19, 2023
1 2 3 4 5 6 7 8...19
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top