Analysis on the decrease of the base temperature of the cooling box after shutdown of the air separation plant

Analysis on the decrease of the base temperature of the cooling box after shutdown of the air separation plant
Mar 22, 2024
Author: DEAR AST
Question Reply

After the air separation equipment stops, when the equipment does not discharge liquid, the basic temperature of the cold box will be reduced to more than - 100C in many cases. Most air separation plant users customers concern about this situation which will lead to a illusion of equipment leakage for the sake of safety.If the base temperature of cold box is reduced due to equipment leakage, the leakage should be more serious when the equipment hold pressure before the system stops. f the base temperature of the system is normal before shutdown, and the base temperature of the cold box decreases to more than minus 100 degrees after shutdown, it must be caused by no heating gas after shutdown of the air separation equipment and the downward diffusion of the cold gas in the fractionator, instead of the leakage of the fractionator.This phenomenon will disappear automatically after the equipment is put into normal operation.

DEAR Air Separation Solve YourAnalysis on the decrease of the base temperature of the cooling box after shutdown of the air separation plantYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top