Analysis on the decrease of the base temperature of the cooling box after shutdown of the air separation plant

Analysis on the decrease of the base temperature of the cooling box after shutdown of the air separation plant
Mar 22, 2024
Author: DEAR AST
Question Reply

After the air separation equipment stops, when the equipment does not discharge liquid, the basic temperature of the cold box will be reduced to more than - 100C in many cases. Most air separation plant users customers concern about this situation which will lead to a illusion of equipment leakage for the sake of safety.If the base temperature of cold box is reduced due to equipment leakage, the leakage should be more serious when the equipment hold pressure before the system stops. f the base temperature of the system is normal before shutdown, and the base temperature of the cold box decreases to more than minus 100 degrees after shutdown, it must be caused by no heating gas after shutdown of the air separation equipment and the downward diffusion of the cold gas in the fractionator, instead of the leakage of the fractionator.This phenomenon will disappear automatically after the equipment is put into normal operation.

DEAR Air Separation Solve YourAnalysis on the decrease of the base temperature of the cooling box after shutdown of the air separation plantYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Small air separation unit is the unit that separates air into oxygen and other gases by first compressing and cooling the air into a liquid state and then using the characteristic that oxygen has a different boiling point to other gases in the air to obtain oxygen and liquid oxygen by evaporation and separation, as well as other rare gases as required.Liquid oxygen is produced using the cryogenic separation of air. The basic principle is to u...
2025.04.02
The pressure relief of molecular sieve in the purification system is generally rapid in the early stage, not complete and running overtime in the later stage. The pressure relief degree is adjusted by the manual stop valve in front of the pressure relief valve. Through practical adjustment, no matter how it is adjusted, the pressure relief in front is fast, or the pressure can not be exhausted. It is suggested that the valve positioner should be added to the automatic pressure relief valve, and the pressure linear adjustment should be programmed, so that the impact on molecular sieve will be much smaller.
2025.04.01
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top