What safety matters should be paid attention to when checking pressure pipelines?

What safety matters should be paid attention to when checking pressure pipelines?
Mar 21, 2024
Author: DEAR AST
Question Reply

For the pipeline with pressure, the easiest problem in the production process is the leakage at the connection flange. Once leakage is found, do not tighten it under pressureBolt. There are some reasons for the leakage in the process of operation, such as gasket damage, pipeline under thermal stress, etc. At this time, just rely on twistingBoltIf the problem can not be solved, often screw the Bolt hard because the leakage has not been eliminated until the bolt is broken, and the high pressure gas in the pipe sprays out, causing injury accidents. There have been several factories that have broken bolts due to the screw bolts with pressure,FlangeLesson from the casualty accident of disc flying.
Therefore, it must be strictly abided by the forbidding of twisting with pressureBoltRules, do not hold fluke mentality in order to seize the time, hurry up with the task, violate the operating rules.

DEAR Air Separation Solve YourWhat safety matters should be paid attention to when checking pressure pipelines?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Liquid air separation plant piston compressor clearance volume is: the compressor at the end of the exhaust, the piston and the cylinder end of the wall between the residual part of the high pressure gas occupied by the cylinder volume. The existence of the residual volume directly reduces the exhaust volume of the compressor, at the same time, the suction of this part of the high pressure gas expansion, will also cause a delay in the suction process, the reduction in suction volume, ultimately ...
2026.02.11
All low pressure air separation units are usually equipped with nitrogen water precoolers. It mainly uses the unsaturation of nitrogen in sewage to evaporate part of water. As the water evaporates, it absorbs the latent heat of vaporization to lower the temperature of the cooling water, which is then used to cool the treated air and lower the temperature of the air entering the column. Therefore, it includes air cooling column and water cooling column. The basic purpose of setting up nitrogen precooler is to reduce the air temperature entering the air separation column and avoid the temperature fluctuation greatly. Because the inlet air temperature directly affects the operation conditions of the switching heat ex-changer and distillation column, as well as the economy of the whole air separation unit. In the design, the air temperature entering the column is usually set at 30 ° C. When the inlet temperature of the column is higher than the design index during operation, the throttl
2026.02.10
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top