Small air separation FAQ

Performance of centrifugal compressor in surge
Aug 23, 2024
Installation process of chemical pipeline of air separation unit
Aug 15, 2024
What are the functions and classifications of distillation column of air separation unit
Aug 07, 2024
What is the purpose of an expansion heat exchanger in an air separation plant?
Jul 30, 2024
Uneven bubbling of sieve tray tower
Jul 22, 2024
How can I check that the cooling water circulation of my air separation plant is fully connected?
Jul 12, 2024
Minimum temperature in air separation column
Jul 05, 2024
What measures to take when the precooling system fails
Jun 27, 2024
Screw compressor bearing burnt out
Jun 19, 2024
During the start-up phase, when the liquid volume accumulates in the condensing evaporator, the gas and liquid mixture will pass through the liquid air and liquid nitrogen throttle valves. When the throttle valve begins to close, due to the large opening of the valve, when the amount of gas and liquid mixture from the lower column to the upper column changes little, and the pressure of the lower column does not increase significantly, it means that the temperature difference of the condensing evaporator has not increased. At this time, the condensing evaporator and the surrounding insulation have been cooled to the low temperature required by the liquid accumulation stage. Due to a large amount of cold production and a large amount of gas liquefaction, the liquid evaporation in the condensing evaporator is also increased. The rising steam produced prevents the flow of liquid from the sieve plate hole, and gradually accumulates liquid on the tray, so the liquid level will drop. In ad
Jun 11, 2024
From the starting characteristics of the motor driving the air compressor, it can be seen that the current of the motor starting is several times larger than that of normal operation. The strong starting current has a great influence on the motor itself, transformer and transmission line. In order to reduce the starting time and starting current, no-load is a more effective measure. Based on this requirement of motor starting, before starting the air compressor, the pressure of all levels of pressure gauges should be checked. If there is air, the air should be released.
May 31, 2024
The quality of air separation plant installation is an important part to ensure the overall quality of air separation plant, so the safety of air separation plant installation is very important. The safety precautions in the installation of air separation plant are summarized as follows. 1. The installation and construction of air separation plant must be carried out in strict accordance with the “Safety Technical Operation Regulations” of the construction unit. 2. The construction personnel of air separation plant must work with certificate, and safety belt must be fastened during climbing operation to ensure safety protection of high-altitude operation. 3. The hot work in the air separation plant area must go through the fire operation procedures, and the fire can be started only after the procedures are complete, and there must be a special person to take care of the hot work process. 4. During the pipeline strength pressure test of air separation plant, other operations
May 23, 2024
1 2 3 4 5 6 7 8...19
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top