Author: DEAR AST

In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:

 

First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;

 

Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be manually closed, and record the program status of molecular sieve adsorber before power failure. Expander, refrigerator, air precooling system and argon purification system shall also be shut down by interlocking, if not, manually;

 

Finally, stop the delivery of oxygen and nitrogen products, stop the output of liquid oxygen, liquid nitrogen and liquid argon, and close the water valve of air precooling system and external connection.

8

DEAR Air Separation Solve YourHow to operate the sudden power failure of small air separation units?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Small air separation unit is the unit that separates air into oxygen and other gases by first compressing and cooling the air into a liquid state and then using the characteristic that oxygen has a different boiling point to other gases in the air to obtain oxygen and liquid oxygen by evaporation and separation, as well as other rare gases as required.Liquid oxygen is produced using the cryogenic separation of air. The basic principle is to u...
2025.04.02
The pressure relief of molecular sieve in the purification system is generally rapid in the early stage, not complete and running overtime in the later stage. The pressure relief degree is adjusted by the manual stop valve in front of the pressure relief valve. Through practical adjustment, no matter how it is adjusted, the pressure relief in front is fast, or the pressure can not be exhausted. It is suggested that the valve positioner should be added to the automatic pressure relief valve, and the pressure linear adjustment should be programmed, so that the impact on molecular sieve will be much smaller.
2025.04.01
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top