How to operate the sudden power failure of small air separation units?

How to operate the sudden power failure of small air separation units?
Nov 21, 2024
Author: DEAR AST

In case of sudden power failure during the operation of small air separation unit, the following steps should be followed:

 

First, open the vent valve (anti surge valve) of air compressor to prevent the air compressor from surging and causing the air compressor to reverse due to air backflow;

 

Then check whether the molecular sieve adsorber switch should be interlocked to close, if not, it should be manually closed, and record the program status of molecular sieve adsorber before power failure. Expander, refrigerator, air precooling system and argon purification system shall also be shut down by interlocking, if not, manually;

 

Finally, stop the delivery of oxygen and nitrogen products, stop the output of liquid oxygen, liquid nitrogen and liquid argon, and close the water valve of air precooling system and external connection.

8

DEAR Air Separation Solve YourHow to operate the sudden power failure of small air separation units?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The main heat exchanger is the key equipment to ensure the performance of the air separation plant. Its functions in the air separation plant of the molecular sieve pre-filtration process are as follows: recover the cooling capacity of the reflux gas, ensure that the heat exchange temperature difference is within the design range; provide sufficient expansion gas in front of the expander to make up for the cooling loss of the air separation plant; provide raw air for the lower tower under the design conditions; and the working medium is in the main heat exchanger The resistance value in meets the process requirements.
2025.12.31
A low pressure nitrogen expander is added to the process design. The pressure nitrogen from the pressure tower and high pressure expander is expanded into low pressure nitrogen, which is combined with the nitrogen coming from the low pressure tower and fed into the charge gas compressor. This is specially set up for rapid oxygen load changes. The oxygen product flow rate during normal operation corresponds to the amount of oxygen contained in the amount of air entering the air separation unit. T...
2025.12.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top