How to operate small air separation plant when the low temperature thermometer fails?

How to operate small air separation plant when the low temperature thermometer fails?
Feb 19, 2024
Author: DEAR AST
Question Reply

Kong fen taThe three-point temperature of low temperature meter is: T3 temperature refers to the temperature before high pressure air throttling; T2 temperature refers to the temperature of air after expansion; T1 refers to the temperature after the first heat exchanger and before the expansion machine. The function of the three-point temperature is mainly to control the gas distribution between the expansion machine and the joint-1 valve during the start-up stage of the air separation tower. There is no need to control the normal and stable operation. If only one or two of the thermometer is out of order, we can speculate the working condition according to the intact temperature point. When the three-point temperature is completely out of order, it can be operated according to the temperature difference between the Heat end of the heat exchanger (namely the temperature difference between the air inlet device of processing air and the outlet temperature of oxygen, nitrogen and distillation, make the temperature difference of the hot end not greater than the normal value.
If the temperature difference of the hot end is in the normal value, try to turn on the cam mechanism as large as possible and turn off the small high pressure air throttle accordingly. When the cam mechanism has been opened to the maximum air intake position, the joint-1 valve can be used to adjust according to the need of liquid oxygen level. If the temperature difference of the hot end is greater than the normal value, open the big section-1 valve and close the small cam mechanism. In this case, the operation should be predictable, and the delayed reaction should be paid attention.
Because the change of temperature difference at the Heat end of the heat exchanger is the result of the internal temperature change of the first and second heat exchanger. When passingExpanderWhen the air is too much, the air volume passing through the joint-1 valve decreases correspondingly, the positive flow air of the second heat exchanger decreases, while the amount of oxygen and nitrogen flowing back remains unchanged, and the function of the second heat exchanger is not fully exerted. On the contrary, the load of the first heat exchanger increases, the cold recovery of the return gas is not perfect, and the temperature difference of the Heat end is enlarged. When starting, the liquid oxygen level is not easy to rise, and when depressurizing, it cannot depressurize. When the temperature difference of the original hot end is relatively large, after adjusting the opening degree of the joint-1 valve and Cam, and the temperature difference of the hot end is close to the normal value, it should be carefully and slowly stabilized. The operation without low thermometer indication depends entirely on personal experience, and the previous operation records can be used as reference.

DEAR Air Separation Solve YourHow to operate small air separation plant when the low temperature thermometer fails?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top