Application of I & C measuring elements in air separation plant

Application of I & C measuring elements in air separation plant
Apr 10, 2024
Author: DEAR AST
Question Reply

When the cryogenic method is used for air separation, the whole process is carried out in closed containers and pipelines from the air compressor to the final gas and liquid products such as oxygen, nitrogen, argon and so on. During the start-up, shutdown and normal operation of the equipment, the values of relevant parameters must be strictly controlled in each process, including pressure, temperature, flow, resistance, liquid level, rotate speed, voltage, current, component analysis, etc. The following introduces some instrument control components for measuring temperature, pressure and flow for reference.

 

1.Temperature measurement:

 

In the temperature measurement of air separation plant, the main measuring elements are platinum thermistor thermometer, temperature transmitter and bimetal thermometer. Platinum thermistor thermometer is widely used in air separation plant due to its high measurement accuracy at low temperature (13.81K) and no temperature compensation at cold end. Temperature transmitter converts platinum resistance and thermocouple signal into standard 4 ~ 20mA signal and outputs it, which is divided into integral type and split type. Bimetal thermometer has simple structure, good precision and small lag It has the advantages of low cost and not affected by ambient temperature and atmospheric pressure. It is mainly used for local temperature indication in air separation.

 

2.Pressure measurement:

 

In the pressure measurement and control of air separation plant, the main measuring elements are pressure transmitter, spring tube pressure gauge and pressure controller. The process pressure of the measured point is detected by the pressure transmitter through a certain detection method, and the signal is transmitted to 4 ~ 20mA. Generally, it can be indicated by the on-site meter, which is convenient for maintenance and debugging. The pressure measuring points that need to be displayed and controlled by DCS need to be measured by pressure transmitter; the spring tube pressure gauge is mainly used for local pressure indication in the air separation plant because of its simple structure, good accuracy, low cost and not affected by the ambient temperature and atmospheric pressure; the pressure controller, also known as the pressure switch, is mainly used for the alarm and interlock of process pressure.

 

3.Flow measurement:

 

In the flow measurement of air separation plant, orifice plate and vortex street are mainly used. Orifice plate throttling device is a flow measurement device without scale, which is used to measure the flow rate of liquid, gas and steam with medium temperature ≤ 400 ℃. The pressure difference generated by the orifice plate is converted into a proportional output signal by the transmitter, and then the measured flow is recorded, indicated or regulated by the secondary instrument or regulator; the thermosensitive vortex flowmeter is used to measure the clean, non corrosive liquid and gas medium with the temperature of - 196 to + 400 ℃. It is suitable for pipes with nominal diameter of DN25-DN200. Air separation is often used to measure the flow of temperature liquid, its output 4 ~ 20mA DC signal into PLC display; electromagnetic flowmeter, air separation for water measurement at room temperature, select electromagnetic flowmeter, its output 4 ~ 20mA DC signal into PLC display.

DEAR Air Separation Solve YourApplication of I & C measuring elements in air separation plantYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The raw air is compressed to about 0.52Mpa by the air compressor after filtering out dust and impurities, and then cooled to about 10℃ by the refrigerant glycol aqueous solution or Freon, and then enters the purification system to purify and remove water, carbon dioxide and other impurities in the air. Part of the raw material air enters the lower tower via the second raw material air pipeline, another part is liquefied into liquid air via the liquefier and enters the lower tower via the liquid ...
2025.12.04
Generally, the main reason for the vibration of piston type oxygen compressor is the action of alternating load. There are two kinds of alternating loads: one is the unbalanced inertia force, the other is the interference force caused by the strong gas pressure pulse in the gas pipeline caused by the discontinuous gas supply of the compressor. The vibration caused by unbalanced inertia force can be eliminated and reduced from the structure of the machine itself. The specific methods are as follows: reasonably arrange the crank stagger angle; properly select the mass configuration of reciprocating parts. In addition, the basic design and manufacturing process of the compressor should also strictly comply with the technical specifications. For the vibration caused by air flow pressure pulse, a buffer can be installed near the cylinder exhaust pipe nozzle; the appropriate installation position of orifice plate should be selected on the gas flow channel; the shock absorber should be
2025.12.03
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top