1) insufficient cooling water. The heat of the air is not enough to be taken away by the cooling water, resulting in the increase of the next level of suction temperature, the decrease of gas density, and finally the reduction of exhaust volume. Therefore, the water supply pressure of cooling water should be closely monitored during operation to control the water supply. The process generally requires that the cooling water pressure should be greater than 0.15MPa (surface pressure );
2) cooling water temperature is too high. High water temperature reduces the temperature difference between water and gas, and reduces the effect of heat and cooling. Even if the amount of cooling water is not reduced, the temperature will still be very high after gas cooling;
3) There are too much scale in the cooling water pipe or it is blocked by sediment and organic matter, as well as moisture precipitation after cooling on the air side of the cooler, which can not be discharged timely, all of which...