当前位置: Home / Faq / Air separation parts FAQ /

Brief introduction of molecular sieve

Brief introduction of molecular sieve
May 23, 2023
Author: DEAR AST
Question Reply

Molecular sieve(Also known as synthetic zeolite) is a kind of microporous crystals made up of SiO and AIO sihedron and the frame structure. There are metal cations (such as Na, K, Ca, etc.) in the molecular sieve lattice to balance the redundant negative charge in the sihedron. According to its crystal structure, the types of molecular sieve are mainly divided into: Type A, Type X, type Y, etc.
TYPE A
5 r H-[2 d4 M + g4 Z % f the main component of r H-[2 d4 M + g4 Z % f is siovenate, with a Aperture of 4A (1A = 10-10 M), which is called 4A (also known as Nano A) molecular sieve; the aperture of 5A is formed by exchanging the Na + in the 4A molecular sieve with Ca +; the aperture of 3A is formed by exchanging the Na + in the 4A molecular sieve with K +, that is 3A (also known as potassium A) molecular sieve.

X-TYPE

The crystal structures of the aluminium silicon are different (the size of the ratio of silicon to aluminum is different), forming the molecular sieve crystal with the aperture of 9-05, which is called 13X (also called sodium X type) molecular sieve; exchange the Na + in the 13X molecular sieve with Ca +, the formation of molecular sieve crystal with a Aperture of 9A is called 10X (also called calcium X type) molecular sieve.

Y-TYPE

Y-type molecular sieve has crystal structure like X-type molecular sieve hydrocarbon, but its chemical composition is different (silicon and aluminum are relatively large), which is usually used in the catalytic field.

DEAR Air Separation Solve YourBrief introduction of molecular sieveYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why do molecular sieves in small air separation unit use bunk beds? Molecular sieve purifiers are used in both small and large air separation plants to purify the air. carbon dioxide, acetylene, and various hydrocarbons. Some molecular sieves small air separation unit use a double bed because the adsorption capacity of activated alumina is relatively large for air with high water content, but as the water content of the air decreases, the adsorption capacity decreases rapidly. The molecular s...
2026.01.29
It should contact with the front and rear processes when the piston compressor is ready to stop, we should pay attention to the following sequence: first, cut off the gas supply slowly. In order to prevent the outlet pressure from rising after the gas supply is cut off, open the vent valve at the same time. For the oxygen compressor, the vent valve should be opened slowly, because excessive opening may produce static electricity and cause fire. Then, stop the motor. After the motor stops, turn off the circulating oil pump, grease injector motor and cooling water valve. However, there are also exception cases. For example, in case of emergency shutdown, in order to save time and prevent the accident from expanding, the power supply can be cut off immediately to stop the compressor with load.
2026.01.28
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top