Relationship between the average temperature of liquid oxygen in an air separation plant and the main cooling liquid level

Relationship between the average temperature of liquid oxygen in an air separation plant and the main cooling liquid level
Mar 21, 2023
Author: DEAR AST

The average temperature of liquid oxygen is related to the level of the main cooler. The higher the level of liquid oxygen in the main cooler, the higher the pressure of liquid oxygen at the bottom of the main cooler, and the higher the evaporation temperature of liquid oxygen. Since liquid oxygen is in a saturated state, the average temperature of liquid oxygen will increase. At this time, if you want to maintain the main cooling temperature difference, you must correspondingly increase the lower tower pressure. Therefore, considering the design, the pressure on the liquid oxygen surface should not be too high. Generally, the height of small and medium-sized air separators is 0.4~0.5m, and the height of large air separators is 1.2~1.8m.

DEAR Air Separation has strong scientific research strength and design foundation in the field of gas technology, and has made outstanding achievements in technical research and product development.

DEAR Air Separation Solve YourRelationship between the average temperature of liquid oxygen in an air separation plant and the main cooling liquid levelYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the process of operation, especially in the start-up and shutdown of the air separation unit, one-way force should be avoided on the instrument. During the start-up of the equipment, close the high pressure and low pressure valves firstly, then open the balance valve, and then slowly open the high pressure (or low pressure) valve, so that the measured medium can enter the positive (negative) pressure chamber of the transmitter. If the liquid is to be measured, the gas in the positive (negative) pressure chamber should be discharged from the upper vent. If the gas is measured, drain the liquid accumulated in the positive (negative) pressure chamber from the lower drain screw hole. After discharging the gas (liquid), close the balance valve, and then open the valve on the other side. When the equipment is shut down, the high pressure (or low pressure) valve should be closed first, then the balance valve should be opened, and then the valve should be closed on the other side. Someti
2026.07.31
What are the reasons why the oxygen production of air separation equipment cannot meet the target
2026.07.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top