Relationship between the average temperature of liquid oxygen in an air separation plant and the main cooling liquid level

Relationship between the average temperature of liquid oxygen in an air separation plant and the main cooling liquid level
Mar 21, 2023
Author: DEAR AST

The average temperature of liquid oxygen is related to the level of the main cooler. The higher the level of liquid oxygen in the main cooler, the higher the pressure of liquid oxygen at the bottom of the main cooler, and the higher the evaporation temperature of liquid oxygen. Since liquid oxygen is in a saturated state, the average temperature of liquid oxygen will increase. At this time, if you want to maintain the main cooling temperature difference, you must correspondingly increase the lower tower pressure. Therefore, considering the design, the pressure on the liquid oxygen surface should not be too high. Generally, the height of small and medium-sized air separators is 0.4~0.5m, and the height of large air separators is 1.2~1.8m.

DEAR Air Separation has strong scientific research strength and design foundation in the field of gas technology, and has made outstanding achievements in technical research and product development.

DEAR Air Separation Solve YourRelationship between the average temperature of liquid oxygen in an air separation plant and the main cooling liquid levelYou can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top