Air separation equipment in the process of operation overload, the main cooling liquid level long not high should be how to solve?

Air separation equipment in the process of operation overload, the main cooling liquid level long not high should be how to solve?
Jul 11, 2024
Author: DEAR AST

Overloading of air separation equipment during operation means that the load of the equipment exceeds its rated load, resulting in unstable behaviour of the equipment, such as noise, vibration and excessive heat. Overload may be caused by bottlenecks in the production process, overloading of production capacity or operational errors. Solutions: Check the air pressure, flow rate and temperature parameters of the equipment and make sure they are within the normal range; ensure that the operating conditions and ambient temperature of the equipment are suitable; limit the load of the equipment to avoid overloading.
The reasons why the main cooling liquid level is not high may include incomplete loss of heat exchange in the main heat exchanger, low efficiency of the expander with small temperature difference, high temperature of air into the main heat exchanger, and leakage of the equipment. Solution: Reasonable distribution of cold, if the heat exchanger is blocked, it should be comprehensively heated and blown out; check the expander and deal with it; check the air-cooling system and molecular sieve adsorber and deal with it; check the cold-retaining materials, check the leakage and deal with it; and reduce the amount of liquid taken out.
There are various technical problems of air separation equipment, DEAR Air Separation has long-term experience in establishing a sound equipment management system and operating procedures, standardising the operation and maintenance process of the equipment, reducing the technical problems of the air separation equipment, and guaranteeing the operating efficiency and reliability of the equipment.

DEAR Air Separation Solve YourAir separation equipment in the process of operation overload, the main cooling liquid level long not high should be how to solve?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
 The purpose of the blowing is to clean out the residual slag, aluminium chips and other debris from the piping and vessels. the air source for blowing is provided by the turbine compressor, and the air cooling tower must be activated. 3. blowing principle, first outside the tower, after the tower, blowing brush to be one after another, in the blowing with the air pressure: low pressure system. Should be maintained at 40 a 50kpa high pressure system: should be maintained at 250 ~ 400k...
2025.07.23
Due to improper adjustment of seal gas pressure during operation, liquid oxygen pump can not pump liquid or leak.   From the quality point of view, when the sealing pressure is too high, there will be gas leakage into the pump through the labyrinth seal, resulting in the impeller with gas or even idling, resulting in liquid injection or pressure drop; when the air pressure before sealing is too low, there will be liquid oxygen leakage.   From the quantity point of view, when (p1-p3...
2025.07.22
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top