How can I check that the cooling water circulation of my air separation plant is fully connected?

How can I check that the cooling water circulation of my air separation plant is fully connected?
Jul 12, 2024
Author: DEAR AST

Checking whether the cooling water circulation is fully connected is an important step to ensure the normal operation of the equipment.
Observe the operation status of the cooling water system and check that the water level in the tank is normal, with no leakage or abnormal drop. Observe the water flow, observe the flow of cooling water through the transparent pipe or observation window. Check the pipeline connection, check all the interfaces of the cooling water pipeline one by one, no leakage or looseness at the interfaces; check that the mounting bracket of the pipeline bracket is stable and no looseness. Check the status of the valves, check whether all the valves in the cooling water system (e.g. globe valves, regulating valves, check valves, etc.) are in the correct working condition. Detect cooling water flow and pressure, install flow meters and pressure gauges and compare design parameters. Check the quality of cooling water and regularly test the water quality: regularly take samples to test the water quality of cooling water, including PH value, turbidity, hardness, chlorine ion content and other indicators. Cleaning and replacing the cooling water, according to the water quality test results, timely cleaning of the cooling system and replacement of new cooling water. Replacement of new cooling water can avoid the deterioration of water quality damage to the system.
Comprehensive inspection and commissioning, comprehensive inspection, based on the completion of the above checks, a comprehensive inspection of the cooling water system. Ensure that the cooling water system can operate normally.

DEAR Air Separation Solve YourHow can I check that the cooling water circulation of my air separation plant is fully connected?You can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Why is the cryogenic air separation air compression system the most power consuming link?
2026.03.23
Screw compressor is a positive displacement compressor from the mechanical type, which is composed of the driving rotor and driven rotor, the main body and a pair of synchronous gears. Therefore, the common faults of screw compressor are as follows: 1. The bearing is burnt out. Because of the foreign matter in the oil system, the oil pressure and the quality of the oil are reduced, resulting in the bearing burning out. The main treatment methods are: check the oil supply system; clean the oil filter and the cooling pipe of the oil cooler; check and adjust the oil pressure regulating valve; test the oil quality, and replace the oil when it is not good; check and deal with the oil leakage points. 2. The rotor is burnt out. When foreign matters enter into the compressed medium system, the temperature of the rotor rises, the temperature of the cooling oil of the rotor increases due to the high temperature of the inhaled medium, and the compression ratio increases, which may cause the
2026.03.20
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top