The small air separation unit pressure leak detection

The small air separation unit pressure leak detection
May 19, 2022
Author: DEAR AST

Due to the age and disrepair of the small air separation unit, the cold box outside the pipeline and flange, valve connections have external leakage phenomenon. This part of the trace leakage for the normal operation of the small air separation unit is not significant, but for the gas tightness of the pressure test has a significant impact. Purified air, booster air.O2, N2, WN in and out of the cold box main exchange cold box flange is the internal thread connection method, not easy to disassemble, workers will be cut in the pipeline to increase the blind plate.

According to the technical requirements of small air separation unit for each system for gas tightness test, booster system residual rate of 99.4%, low and medium pressure system residual rate of 98.3%, in line with technical requirements, after the new weld and part of the old weld flaw detection test.

After several days of commissioning and operation, the oxygen and nitrogen output of the air separation equipment met the standard, and the argon equipment produced qualified liquid argon products with the same output purity as before the overhaul. After the correction of the liquid-air analysis measurement point analysis results and liquid level at the positive pressure tube is basically the same. The oxygen meter was used to measure the western measurement point of the cold box and other locations, and the oxygen content was basically O. The upper and lower pressures of the cold box were 80, 245 and 320 respectively. no frost and ice on the surface of the cold box, which achieved the expected overhaul effect of the small air separation unit.

Innovative research and development is the cornerstone of an enterprise to maintain lasting competitiveness. Take Kaifeng DEAR Air as an example, the reason why it has a strong R & D strength in small air separation unit, large air separation unit and liquid air separation plant design. First of all, thanks to the early and international giants of long-term in-depth cooperation.微信图片_20200102093128

DEAR Air Separation Solve YourThe small air separation unit pressure leak detectionYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top