Overhaul of condenser of small air separation units

Overhaul of condenser of small air separation units
May 20, 2022
Author: DEAR AST

1 main exchange cold box and the main cold box between the partition, process pipeline through the partition using the insulation plate plus wool felt cold way, its poor cooling effect, resulting in the partition, column channel steel frost cracking. So the workers changed to open DN600 hole on the partition plate plus stainless steel collar, the collar with foam foam to keep cold, welding reinforcement of frozen cracked channel steel branch.
2 original process pipeline fixed using stainless steel clamps wool felt appears more loose, check all process pipelines, according to the new specifications to increase the bracket as follows
3The blow-off pipe line of the liquid argon return pipe of the crude argon condenser (Φ30×2), increase the fixed frame and guide frame
4 The liquid-air return line of the crude argon condenser to the upper tower (LAΦ30×2-L), add fixed frame and guide frame near the exit end of the crude argon condenser. Replace the pipe before and after the manual valve V701, make brackets for each of the main tower crude argon II tower, and add fixed brackets before the inlet of the upper tower.
5 crude argon condenser process argon to fine argon tower pipeline (GA-Φ70×3--), the original pipe rack removed, in the original position to increase the fixed in the crude argon tower II fixed pipe rack, process argon discharge pipe in the middle of the fine argon tower to increase a guide rack.
6 liquid air into the crude argon condenser pipeline (LA-①110×4-L) the upper part of the original pipe rack was removed and replaced with a fixed pipe rack on the crude argon tower from the top to the first pipe rack near the cold box was changed to a frame type sliding rack.
The small air separation unit, large air separation unit and liquid air separation plant overhaul team at DEAR Air is experienced in overhauling condensers.缅甸钢铁公司-1500

DEAR Air Separation Solve YourOverhaul of condenser of small air separation unitsYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The air cooling tower is the core equipment of the air separation precooling system, which is mainly used to cool and wash the high-temperature compressed air discharged from the air compressor, provide qualified low-temperature gas source for subsequent molecular sieve purification and cold box rectification, and ensure the stable operation of the whole unit. The air cooling tower adopts the countercurrent packing heat exchange structure, the tower is filled with high-efficiency packing, and the top is equipped with a spray device and a wire mesh demister. During operation, the high-temperature compressed air at 80 to 100 ℃ discharged by the air compressor enters from the bottom of the tower and flows from bottom to top; The cooling water is the normal temperature make-up water and the low-temperature chilled water prepared by the water-cooling tower, which is sprayed from top to bottom from the tower top, and the air and water are fully contacted in reverse for heat exchange. Under t
2026.11.12
Regulation of liquid nitrogen throttle valveThe opening of the liquid nitrogen throttle valve not only affects the reflux ratio of the upper tower, but also affects the reflux ratio of the lower tower. When the opening is increased, the reflux ratio of the upper tower increases, while the reflux ratio of the lower tower decreases, the purity of the nitrogen in the upper tower increases, and the purity of the oxygen enriched night sky in the lower tower increases. However, after the opening is over, the purity of the liquid nitrogen decreases, and the reduction of the reflux ratio of the upper tower is also detrimental to the improvement of the purity of the liquid oxygen. Therefore, an equilibrium point should be found for the opening of the liquid nitrogen throttle valve. We can generally use the purity difference between liquid nitrogen and gas nitrogen to judge whether the opening is appropriate. Generally, the purity of the sprayed liquid nitrogen is equal to that of the upper towe
2026.11.11
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top