Liquid air separation plants argon maintenance

Liquid air separation plants argon maintenance
May 20, 2022
Author: DEAR AST

Due to deformation, the pipeline of the liquid-air steam of the crude argon tower back to the safety valve of the upper tower needs to be re-piped.Fine argon tower condenser liquid nitrogen discharge pipe, add fixed frame below the condenser, add guide frame in the middle of the fine argon tower. In close proximity to the crude argon tower inlet liquid argon pump outlet to the crude argon tower pipeline to a fixed frame, liquid argon pump outlet pipe from the bottom to the first straight section of the top elbow down about 1.5 m position to increase the fixed frame fixed on the cold box plate.

Due to deformation, the safety valve tube on the nitrogen out of the fine argon tower condenser line needs to be replaced and the bracket installed on the cold box.The disconnected fine argon tower evaporator non-condensable gas blow-off tube is restored, the fixed bracket is installed on the evaporator. Replacement of liquid argon metering tank to the fine argon tower deformation serious argon gas pipeline, fixed frame installed on the evaporator. Fine argon tower evaporator liquid nitrogen export line due to deformation need to re-piping, bracket and fixed frame installed in the evaporator body.Lower tower pressure nitrogen to fine argon tower evaporator pipeline, in the nitrogen inlet valve, the valve before the fixed frame, lower tower pressure nitrogen out of the lower tower pipeline to restore.

The automated production line with intelligent MES bus control system enables DEAR intelligent production line to achieve automatic order scheduling and automatic equipment optimisation for production. The intelligent production line not only reduces manpower work by 90%, but also allows lean management of the intelligent system, greatly reducing material costs and doubling production capacity of small air separation units, large air separation units and liquid air separation plants陕鼓集团-36000

DEAR Air Separation Solve YourLiquid air separation plants argon maintenanceYou can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
What is the oxygen internal compression process
2026.03.27
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top