What factors can affect the cooling effect of the intermediate cooler of the compressor, and what influence does the poor Intermediate cooling have on the performance of the compressor?

What factors can affect the cooling effect of the intermediate cooler of the compressor, and what influence does the poor Intermediate cooling have on the performance of the compressor?
Jan 09, 2025
Author: DEAR AST
Question Reply

Air compressorThe intermediate cooler is generally of shell-and-tube structure. Water is supplied inside the pipe, and gas is supplied between the pipes, which plays a cooling role through the heat exchange of fluid inside and outside the pipe. The reasons that affect the cooling effect of compressor intermediate cooler include:
1) insufficient cooling water. The heat of the air is not enough to be taken away by the cooling water, resulting in the increase of the next level of suction temperature, the decrease of gas density, and finally the reduction of exhaust volume. Therefore, the water supply pressure of cooling water should be closely monitored during operation to control the water supply. The process generally requires that the cooling water pressure should be greater than 0.15MPa (surface pressure );
2) cooling water temperature is too high. High water temperature reduces the temperature difference between water and gas, and reduces the effect of heat and cooling. Even if the amount of cooling water is not reduced, the temperature will still be very high after gas cooling;
3) There are too much scale in the cooling water pipe or it is blocked by sediment and organic matter, as well as moisture precipitation after cooling on the air side of the cooler, which can not be discharged timely, all of which will affect the heat transfer area or the heat transfer working condition, and affect the cooling effect. The cooling effect is not good, which makes the temperature of the next level rise, affects the performance curve of the next level, and reduces the outlet pressure and flow. The change of the performance curve of a compressor obtained from the experiment when the temperature of cooling water rises from 10℃ to 30℃. In addition, when the suction volume of the lower level is reduced, it will cause that the air produced by the former level can not be "eaten in" completely, and it is easy to make the work of the former level enter into the surge area, and surge occurs at this level.
Treatment methods include: check the temperature and pressure of the upper water and make adjustments; if the temperature and pressure of the upper water are normal, stop and disassemble to check, use physical and chemical methods to clean or replace the cooler; if the cooler leaks, replace the cooler.

DEAR Air Separation Solve YourWhat factors can affect the cooling effect of the intermediate cooler of the compressor, and what influence does the poor Intermediate cooling have on the performance of the compressor?You can also learn about otherAir separation parts FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
Its essence is to seek the optimal balance between the "lower tower separation effect" and the "upper tower feed quality". Liquid air serves as the bottom product of the lower tower and also as the feed for the upper tower. If the oxygen content is below 36%, it indicates that the reflux ratio of the lower tower is too high, and there is too much nitrogen in the liquid air. After entering the upper tower, it increases the separation burden of the distillation section, resulting in a decrease in oxygen extraction rate; If the oxygen content is higher than 40%, it reflects insufficient separation in the lower tower, often accompanied by a synchronous decrease in liquid nitrogen purity, and an imbalance in load distribution between the upper tower distillation and extraction sections, affecting the quality of nitrogen gas at the top. The raw air contains about 21% oxygen and is initially distilled and concentrated to 36% to 40% in the lower tower, which is the cost-effective balance point
2026.11.27
The purity of liquid air and liquid nitrogen is the core indicator for the operation of air separation distillation tower, which directly determines the quality of subsequent oxygen and nitrogen products. Controlling purity requires a systematic approach from three aspects: distillation conditions, cooling balance, and operating parameters. Firstly, stabilizing the pressure and temperature of the distillation tower is fundamental. Pressure fluctuations in the lower tower can cause gas-liquid equilibrium drift, resulting in changes in liquid air purity. The lower tower pressure should be maintained near the design value to avoid significant fluctuations; Simultaneously monitor the temperature difference of the main condenser evaporator. If the temperature difference is too large, it indicates insufficient liquid nitrogen purity or abnormal liquid oxygen level. Secondly, control the reflux ratio reasonably. The ratio of liquid nitrogen reflux rate to rising gas volume determines the dist
2026.11.26
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top