How to judge the leakage of liquid air and liquid nitrogen supercooler?

How to judge the leakage of liquid air and liquid nitrogen supercooler?
Dec 08, 2023
Author: DEAR AST
Question Reply

Liquid air and liquid nitrogen supercooler uses nitrogen as cold source to cool liquid air or liquid nitrogen. There are Pipe type and plate type cooling device. When leakage occurs, it will affectFractionating towerThe normal work. It can be divided into two situations:
1) liquid air and liquid nitrogen leak to the nitrogen side. Since the liquid air leaks to the nitrogen side, it will be further recovered in the heat exchanger, so the increase of cold loss is not obvious, but the temperature at the cold end is Ding. Will drop, the cold end is too cold. If it is liquid leakage, because of the low concentration of nitrogen in liquid, the leak into the gas nitrogen will make the purity of gas nitrogen decline. After the leakage of liquid, the amount of liquid going into the tower will decrease and the recirculation fluid will decrease, which will worsen the rectifying working condition and decrease the oxygen output. In severe cases, the distillation tower will not work normally.
2) outside the gas and nitrogen leak. This usually happens at the weld joint or flange of the connection pipe. When the gas and nitrogen leak out, the amount of gas and nitrogen entering the heat exchanger will decrease, the supercooling degree of the liquid will decrease, and the gas rate will increase after throttling. At the same time, because this part of nitrogen which has not been reheated is leaked out through the heat insulating material, the production of gas and nitrogen will decrease, the cold loss will increase, the shell will Frost, and the liquid oxygen level of the condensing evaporator will decrease.
In order to further judge whether the liquid air and liquid nitrogen supercooler leak or notFractionating towerParking for heating. Separate the medium-voltage system from the low-voltage system, try to avoid air leakage, and then test the pressure of the medium-voltage system and the low-voltage system respectively. If the medium pressure system rises to the working pressure, the low pressure system has gas or the low pressure system rises to the working pressure, when the medium pressure system has gas, in the case of excluding condensation evaporator, liquid throttle valve, liquid nitrogen throttle valve and other middle and low pressure connection valve without leakage, it can be further confirmed that the leakage of liquid air and liquid nitrogen supercooler. At this time, the Pearl sand should be removed and dismantled.

DEAR Air Separation Solve YourHow to judge the leakage of liquid air and liquid nitrogen supercooler?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
In the liquid air separation plant, the cooled refrigerant goes to the air machine through the refrigerant delivery pipeline, and the intercooler cools the compressed air to around 10°C, improving the efficiency of the air compressor and reducing the energy consumption of the air compressor. The air separation unit uses circulating nitrogen to recycle and utilise the CNG cold through a heat exchanger, which in turn liquefies the air to transfer the cold to the liquid air separation plant, an...
2026.03.31
The plant operation cycle between two large heating is related to many factors. From an operational point of view, this mainly depends on when the air passage of the main heat exchanger is blocked. The main reason for the blockage is that the moisture and carbon dioxide content in the air entering the unit exceeds the standard, which accumulates and freezes in the main heat exchanger until it is blocked. The abnormal operation of molecular sieve purification system will shorten the operation cycle of the unit. It is mainly caused by the following reasons: 1. The molecular sieve adsorption bed is short circuited. In the process of operation, due to the unstable gas velocity control or switching, the pressure difference between the two tanks is too large, which will affect the bed layer, make the molecular sieve bed uneven and make the bed layer short circuit. In serious cases, the dust screen of the adsorber will break and the molecular sieve powder will enter the heat exchanger c
2026.03.30
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top