当前位置: Home / Faq / Liquefied air separation FAQ /

How to judge the leakage of liquid air and liquid nitrogen supercooler?

How to judge the leakage of liquid air and liquid nitrogen supercooler?
Dec 08, 2023
Author: DEAR AST
Question Reply

Liquid air and liquid nitrogen supercooler uses nitrogen as cold source to cool liquid air or liquid nitrogen. There are Pipe type and plate type cooling device. When leakage occurs, it will affectFractionating towerThe normal work. It can be divided into two situations:
1) liquid air and liquid nitrogen leak to the nitrogen side. Since the liquid air leaks to the nitrogen side, it will be further recovered in the heat exchanger, so the increase of cold loss is not obvious, but the temperature at the cold end is Ding. Will drop, the cold end is too cold. If it is liquid leakage, because of the low concentration of nitrogen in liquid, the leak into the gas nitrogen will make the purity of gas nitrogen decline. After the leakage of liquid, the amount of liquid going into the tower will decrease and the recirculation fluid will decrease, which will worsen the rectifying working condition and decrease the oxygen output. In severe cases, the distillation tower will not work normally.
2) outside the gas and nitrogen leak. This usually happens at the weld joint or flange of the connection pipe. When the gas and nitrogen leak out, the amount of gas and nitrogen entering the heat exchanger will decrease, the supercooling degree of the liquid will decrease, and the gas rate will increase after throttling. At the same time, because this part of nitrogen which has not been reheated is leaked out through the heat insulating material, the production of gas and nitrogen will decrease, the cold loss will increase, the shell will Frost, and the liquid oxygen level of the condensing evaporator will decrease.
In order to further judge whether the liquid air and liquid nitrogen supercooler leak or notFractionating towerParking for heating. Separate the medium-voltage system from the low-voltage system, try to avoid air leakage, and then test the pressure of the medium-voltage system and the low-voltage system respectively. If the medium pressure system rises to the working pressure, the low pressure system has gas or the low pressure system rises to the working pressure, when the medium pressure system has gas, in the case of excluding condensation evaporator, liquid throttle valve, liquid nitrogen throttle valve and other middle and low pressure connection valve without leakage, it can be further confirmed that the leakage of liquid air and liquid nitrogen supercooler. At this time, the Pearl sand should be removed and dismantled.

DEAR Air Separation Solve YourHow to judge the leakage of liquid air and liquid nitrogen supercooler?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
The molecular sieve used in oxygen generators is the zeolite molecular sieve. It is a crystalline silica and aluminate polyhydric compound. Molecular sieves have a uniform pore size and their main function is to sieve molecules. There are three main types of molecular sieves: A, X and Y. The 13X molecular sieve is the only adsorbent currently used in liquid air separation plants. Any molecules that can be adsorbed on 3A, 4A and 5A molecular sieves can be adsorbed by 13X molecular sieves. It is c...
2026.09.30
Pressure test before valve installation 1. In the warranty period, those with the certification and the sealing surface is intact can no longer conduct the strength test alone, but only the air tightness test can be taken before installation. 2. Within the warranty period, it has the certificate, and its sealing surface has defects such as corrosion and damage. After treatment, it must carry out the air tightness test. 3. Outside the warranty period, those with certification and intact sealing surface shall be subject to air tightness test before installation. 4. For valves that need to be degreased and disassembled on site, air tightness test shall be conducted separately before installation. 5. The safety valve shall be sent to the local quality inspection department of the project for verification before the end of installation and commissioning.
2026.09.29
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top