当前位置: Home / Faq / Liquefied air separation FAQ /

What is phase cooling method? What are its advantages and disadvantages?

What is phase cooling method? What are its advantages and disadvantages?
Oct 18, 2023
Author: DEAR AST
Question Reply

Phase cooling method adopts switching heat exchanger to self-remove moisture and carbon dioxideAir separation equipmentOne of the starting operation force methods. In the full low pressure air separation plant, under the operating pressure of 0.5MPa (surface pressure), the moisture content is-40 ~ -60℃ has been basically frozen. However, carbon dioxide will not be precipitated and frozen until it is below-133 ℃ until-165 ~ -170℃ frozen. Thus, the range from-60℃ to-133 ℃ is dry zone. Using this principle, the cooling process of the equipment during the start-up operation is carried out in stages, which is the stage cooling method. The whole cooling process is divided into four stages: the first stage is the stage of moisture precipitation and freezing. In this stage, only the switching heat exchanger is first cooled until the temperature at the cold end reaches-60℃; the second stage is drying stage, and the available water has been cleared, while for the machine which has not been eluated out of carbon dioxide, the initial cooling of other equipment will end when the temperature of expansion machine reaches-130℃; the third stage is the stage of eluating out carbon dioxide. In this stage, only the switching type heat exchanger is cooled down to let the carbon dioxide freeze in the heat exchanger and be carried out by the low pressure return gas until the temperature at the cold end reaches-170℃; the fourth stage is to use the purified low temperature gas to further cool other equipments until the liquid is accumulated in the tower, and then further adjust the rectification working condition.
The method for eachAir separation equipmentThe cooling is carried out in stages, so the cooling is uniform and the thermal stress is small. In addition, due to the large amount of cooling required by each equipment in the cooling tower in the second cooling stage, the expansion machine runs for a longer time at a higher inlet temperature, thus, it can give play to the feature of large refrigerating capacity of the turbine expander under high temperature and shorten the start-up time. However, due to the need of repeated cooling of the equipment,ValveThere are many times of opening and closing, and the operation is relatively complex.

 

DEAR Air Separation Solve YourWhat is phase cooling method? What are its advantages and disadvantages?You can also learn about otherLiquefied air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
What is the principle of the deep cooling method of air separation?
2024.04.26
What are the reasons why the main cooling liquid level of the air separation equipment is not high and how to solve it?
2024.04.25
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top