Air separation equipmentReasons and elimination methods of oil leakage failure of air compressor:

There are three types of common failures in the use of air compressor: oil leakage failure, overheating failure and abnormal sound failure, which are analyzed and solved by classification below.

Failure phenomenon: in the daily operation of the air compressor, the oil leakage phenomenon of the air compressor often occurs, and lubricating oil overflows outside.

Cause of failure:

1. Oil seal falls off or oil seal defects leak oil.

2. The loose and open main shaft causes oil seal leakage.

3. The joint surface leaks, and the inlet and return oil pipe joints are loose.

4. If the belt is installed too tightly, the bearing bush will be worn.

5. Casting or processing defects can also cause oil leakage of the air compressor.

Exclusion method:

1. When the air compressor leaks oil, pay attention to observing the oil seal position, and check whether the oil seal is cracked, and whether the inner lip is cracked or flanged. One of the above situations should be replaced; valve imported pump industrial washing machine

2. Check whether there are scratches and defects on the joint surface of Oil Seal and main axis, and replace those with scratches and defects.

3. Check whether the oil return is smooth or not. If the oil return is not smooth and the pressure of the crank box is too high, the oil seal will leak or fall off. The minimum diameter of the oil return pipe must be guaranteed, and it will not be twisted or bent and the oil return will be smooth.

4. Check the matching size of the oil seal and the box, and replace those that do not meet the standard.

5. Move the main axle hard to check whether the neck clearance is too large. If the clearance is too large, the bearing bush and oil seal should be replaced at the same time.

6. Check the sealing condition of each joint sealing pad, repair or replace the sealing pad; check the Bolt of the oil Inlet and return joint and the screw thread of the box and tighten it.

7. Check the oil leakage of the air compressor and readjust the tightness of the belt. Press 10mm with your thumb.

8. If the air compressor leaks oil, it is necessary to check the defects existing in the casting or processing of the box body, and repair or replace the defective parts.

DEAR Air Separation Solve YourReasons and elimination methods of oil leakage failure of air compressorYou can also learn about otherSmall air separation FAQ about DEAR Air Separation, and solve the problem for you.
Didn’t find the problem encountered?
Please contact live chat or email for quick help.
Related FAQ
More Related FAQ
An argon tower is added to the air separation unit to extract crude argon. The main tower is the source of argon components. Its structure and working condition stability directly affect the operation of the argon tower, and there are strict requirements for the design and operation of the main tower. The argon content in the air is about 0.932%, which is mainly concentrated at the argon fraction extraction port in the middle of the upper tower. The upper column of the main tower shall have enough theoretical plates to ensure the preliminary separation of oxygen, nitrogen and argon and produce stable argon fraction. If the separation efficiency of the tray is poor and the oxygen and nitrogen impurities in the argon fraction fluctuate greatly, the argon tower load will be increased and the working condition of the argon tower will be disordered. The argon fraction extraction port should be precisely set in the area with the highest argon concentration in the upper column, and the oxygen
2026.11.25
In the air separation refrigeration system, isentropic expansion and throttling expansion are two core cooling methods. The essential difference between the two determines the significant difference in refrigeration efficiency and application scenarios. Isentropic expansion is a process in which high-pressure gas drives the impeller to rotate through the expander and outputs shaft work to the outside. Under the ideal reversible condition, the entropy remains unchanged, that is, Δ s=0, and the internal energy is directly converted into mechanical work and removed from the system, so the cooling range is large and the cooling capacity is strong. There is a slight entropy increase in actual operation, which is close to the ideal degree measured by isentropic efficiency in engineering. Modern large and medium-sized air separation units use the isentropic expansion of the turbine expander as the main refrigeration source, and the expansion power can also be recovered for pressurization to f
2026.11.24
Need more information?
Contact us for more details about our air separation equipment, solutions and services.
Products
  • Large air separation
  • Small air separation
  • High purity nitrogen air separation
  • Liquefaction air separation
  • Complete air separation
  • Biogas purification
  • Air separation parts
Need more information?
Tel:+86-19837850537
© Kaifeng DEAR Air Separation Industry Co., Ltd.. All rights reserved.
Online
Inquiry
Email
Top